5.4.1
MEASUREMENTS MENU
The initial screen that the DLTM4 comes to is the Measurements Menu. The Measurements menu is depicted in Figure 8.
The Measurements Display provides status of the currently running test. The Clear (F5) button clears out any current
measurements and allows the test to continue running. The action field is associated with the send button. The action field
allows the user to select between different actions to perform during a test. The table bellows describes the actions.
Table 3: Selectable Definitions of the actions field on the Status Screen
Selectable Function
Definition
Insert Error
Invert a single bit in the output bit stream
Insert Slip
Cause a bit slip resulting in loss of receiver lock
Start Zero
Force the output stream to all Zeros
Stop Zero
Restore normal output data stream
Force Resync
Force the receiver correlator to resynchronize
Freeze Display
Freezes the current values on the display
Update Display
Restores the measurement process
Test link delay
Initiates the data link delay process – Only valid for PRN on a “Clean Link.”
Pressing the send button on the touch-screen performs the actions in the action field.
The other fields on the right (F1-F4) bring up the screen for different menus. See the following sections for descriptions
of these screens.
F1
F2
F3
F4
F5
Figure 8: Measurements Menu