AC LINE: If the LED indicator of local power grid is on, that implies connection
with the power grid and that the status is normal. If the LED is flashing, it
implies a connection is made yet an abnormal status of the power grid occurs
(over voltage, under voltage or exceed stable voltage range).
AC CHARGE: If the LED indicator of local power grid charger is on, that
implies the built-in AC charger is charging a battery. If the LED is flashing, it
implies the AC input is available yet the AC charger is not operating.
PV CHARGE: If the LED indicator of Solar MPPT charging controller is on, that
implies the solar panels are charging to the battery bank through the MPPT
built in the PV inverter. If the LED is flashing, it implies the PV input is
LED display panel: To display the operating status, loading capacity, battery
voltage and other information
.
Function setting button: Operation mode, output voltage, frequency and
power saving mode, and other function settings.
Wall mounting hole.
2.2
Front Panel LED Display
LED Display
Loading
LED 1 ON
0~25%
LED 1~2 ON
26%~50%
LED 1~3 ON
51%~75%
LED 1~4 ON
76%~100%
LOAD: Output load indicators display the existing load capacity.
AC LINE
AC CHARGE
PV CHARGE
BATTERY
100%
75%
50%
25%
100%
75%
50%
25%
LOAD
INVERTER
BY PASS
Run
Min.ALM
Maj.ALM
Setting
Figure 2.2: Front Panel LED Display
BATTERY: Battery capacity indicators display the battery residual capacity
.
LED Display
Battery Capacity
LED 1 ON
0~25%
LED 1~2 ON
26%~50%
LED 1~3 ON
51%~75%
LED 1~4 ON
76%~100%
Smart HF Series
Single-phase
PV
Off
-
grid
Inverter
--
Display
Panel
Introduction
available yet the PV controller is not operating.
INVERTER: If the LED indicator of inverter mode is on, that implies the PV
inverter is converting electricity from the battery bank to the AC output and
feed to the loads.
BY PASS: Bypass power indicator with the “ON” implying the local power grid
through the built-in relay in PV inverter is feeding the loading devices.
RUN: PV inverter's operating indicator with the “ON” implying the PV inverter
is started and at a normal operating status that it can supply an AC voltage to
the loading devices.
Min. ALM: PV inverter's warning indicator with the “ON” implying a warning
notice that to be handled without delay. There will be intermittent alarm go off
to remind the users despite the PV inverter can still supply output power to
loading devices.
Maj. ALM: PV inverter's malfunction indicator with the “ON” implying the PV
inverter cannot operate normally due to a fault that the user is required to
troubleshoot the issue immediately.
2.3 Rear Panel Display
A
B
Figure 2.3.1: Overview of the rear panel for rack-mounted smart HF series PV off-grid inverter.
A
C
D
B
C
D
E
E
Input and Output Terminals: Including the local power grid AC input terminals
(L, N), inverter AC output terminals (L, N), and grounding terminal.
PV Input Terminal (PV+, PV-).
Battery Input Terminals (BAT+, BAT-).
Fan Exhaust Vent.
Overcurrent protection device for local power input.
Smart HF Series
Single-phase
PV
Off
-
grid
Inverter
--
Display
Panel
Introduction
11/36
PROFESSIONAL
INNOVATIVE
BRANDING
SERVICE
10/36
PROFESSIONAL
INNOVATIVE
BRANDING
SERVICE
A