6.0 Maintenance Schedule
The following periodic maintenance
schedule
is the suggested minimum requirements and
at
minimum intervals; accumulated hours or monthly period, whichever comes sooner. If you
hear a noise or see any indication of possible failure - cease operation immediately and
inspect, correct and/or replace parts as required. Following these maintenance procedures
is the key to prolonging the life or your lift. We highly recommend using a
n
APlusLift
a
uthorized
t
echnician for all repairs
and modifications.
I F AT AN Y T I M E Y OU
A
RE N OT SU RE OF T H E SAFE OPERAT I ON OF T H E
LI FT,
STOP
U S
ING
I T AN D CALL Y OU R DI ST RI BU T OR FOR ASSI STAN CE.
Warning OSHA and ANSI require
APlusLift
authorized users
to inspect lifting equipment at the start of every shift. These
and other daily periodic inspections are the responsibility of
the user.
6.1 Daily Pre-Operation Check
The user should at least perform the following checks daily.
•
Da ily c he c k of
s
a fe t y
l
oc k ing/
l
a t c h
s
yst e m is ve r y im port a nt - t he disc ove r y
of de vic e fa ilure c ould sa ve you from e x pe nsive prope rt y da m a ge , lost
produc t ion t im e , se rious pe rsona l injur y a nd e ve n de a t h.
• Check to
e
nsure
that the
safety latches
are
free
ly
mov
ing
and full engage
d
.
• Check pneumatic connections, and hoses for leakage.
• Check the
c
ylinder
r
od, if it becomes dry, lightly oil it.
• Check all bolts, nuts, shafts, retaining clips, retainer rings, set screws and screws, ensure
they are aligned (grooves), secured, and tightened properly. Pivot
s
haft set
screws should
always be checked to ensure that they are tight.
• Keep lift free of dirt, grease or any other corrosive substances.
• You should use an oil air regulator to keep the
c
ylinder dry and clean from contamination of
the
a
ir
c
ompressor
• Release the water from your
a
ir
c
ompressor daily to
e
nsure
that
no water contaminates the
f
oot
p
ed
a
l,
h
ose and
h
ydraulic
c
ylinder.
• The
o
iler should supply a mist of oil to the
f
oot
p
ed
a
l,
h
ose and
h
ydraulic
c
ylinder for
lubrication every 10 cycles up and down.