background image

 

12 

 

tighten one side a half dozen turns then the opposite side a half dozen turns. After getting both cables equally tight(YOU 

SHOULD BE ABLE TO MOVE THE CABLES ABOUT AN INCH BACK AND FORTH WITH SLIGHT PRESSURE 

LIKE A FAN BELT OR A BANJO STRING) raise the lift all the way up by pressing the UP Button on the power unit. Do 

not bottom the lift out at the top by holding down on the switch. 

 

Raise the lift off the latch(lock) by pushing the power button, this will enable you to pull each release cable ring 

located at the bottom of both carriages. See Figure 6. Pull down on the lowering valve handle(lever) on the power unit and 

lower  the  lift  all  the  way  to  floor.  Raise  the  lift  again  and  listen  for  the  clicking  of  the  safety  locks  in  each  column. 

Determine which side is slower and tighten the adjusting bolt on the opposite side carriage

. Remember to only tighten 

a few turns at a time until the both locks click at the same time when raising the lift. Cycle the lift up and down. Repeat the 

adjustment until the carriages are within a 1/4

 of each other or the clicks are almost at the same time with each side. When 

cables are adjusted properly they should be fairly tight.  

 

DUAL POINT LOCK RELASE  

 

Figure 5 

 

FINAL ASSEMBLY  

 

Check all bolts and nuts to make sure they are tight. Do not use an impact gun on concrete Anchors.  

 

Check all fittings or leaks. If necessary, make sure the arm lock restraints are engaging properly and smoothly. If 

not, tap the main lock forward or backward as needed with a rubber mallet to insure proper engagement on all 4 gears with 

the arm restraint locks.  

 

Cycle lift up and down to insure carriages are synchronized. 

 

Place a vehicle on the lift and raise until swivel pads are contact with frame of the vehicle. Raise the vehicle about 

3 feet and lower until the tires touch the floor. Keep raising and lowing the vehicle. Increase the height each time until the 

vehicle is completely to top. This procedure pumps all the air from the system.  

TESTING AND ADJUSTING LIFT 

 

With the power properly hooked up and hydraulic oil in the Pump Reservoir, push the Push Button on the side of 

the Motor to raise the Carriages off the locks. Release the Push Button and then pull the Lock Release Cable under each 

carriage to release the locks. Run the lift all the way up and down two more times to bleed all the air from the system.  

Summary of Contents for HW-9KOH

Page 1: ...1 INSTALLATION MANUAL OPERATION INSTRUCTIONS OVERHEAD CAR LIFT 2 POST LIFT AUTO HOIST APlusLift HW 9KOH...

Page 2: ...rface Only on concrete surface a minimum of 4 thick and 3 500 psi tensile strength with steel or fiber mesh reinforcement DO NOT install this lift over concrete expansion joints or cracks Check with y...

Page 3: ...3 Caution Labeling Exemplification...

Page 4: ...4 TABLE OF CONTENTS 1 INTRODUCTION 2 INSTALLATION OPERATION 3 MAINTENANCE SAFETY...

Page 5: ...mns 16 Hex Bolts washers nuts for column extensions mounting to columns 4 lift arms 4 Arm pins Connect arms to carriage 1 Power Unit 220 Voltage single phase w manual release handle 4 Bolts washers nu...

Page 6: ...6 Fig 1 Diagram...

Page 7: ...7 Fig 2 Minimum size of a SLAB L100 x W216 x H6 3000PSI Or Two concrete footings 2 ft x 2 ft with 30 deep 3000PSI...

Page 8: ...are inside the columns or banded to the columns Remove the power unit box four swing arms from the lift next remove the bolts holding the two columns together Remove the top column from the bottom col...

Page 9: ...the cylinders are properly seated into the cylinder hole in the base plate If they are the round part of the cylinder will be sitting down on the steel flat Take the equalizer cables Using vise grips...

Page 10: ...Connect the short hose to 4 3 inches extended fitting in bottom of cylinder Connect Long hydraulic hose to the TEE fitting in power unit Run the long hose up the side of column Run the hose cross the...

Page 11: ...wire length more than 10mm wire size should be 4MM2 Diagram of electrical system for single phase MOTOR M1 Motor KM Contactor SB Button SQ Limit Switch HYDRAULIC FLUID Remove the vent plug from the to...

Page 12: ...e almost at the same time with each side When cables are adjusted properly they should be fairly tight DUAL POINT LOCK RELASE Figure 5 FINAL ASSEMBLY Check all bolts and nuts to make sure they are tig...

Page 13: ...proper weight distribution center of gravity should be midway between adapters Swing arms under vehicle to allow adapters to contact at the manufacturer s recommended pick up points Use caution before...

Page 14: ...all bolts and nuts every six months Hydraulic Oil If your lift will raise all the way to the top of the hydraulic tank is full of hydraulic oil The hydraulic oil should be changed once a year along w...

Page 15: ...ds Never use lift to raise one end or side of vehicle Always raise vehicle about 3 and check stability by rocking vehicle Prior to lowering vehicle walk around the lift and check for any objects that...

Page 16: ...ASE OPERATION IMMEDIATELY Inspect correct and or replace parts as required Daily Pre Operation Check 8 Hours 1 Check safety lock audibly and visually while in operation 2 Check safety latches for free...

Page 17: ...d rollers Replacement of cables and sheaves Replacement or rebuilding air and hydraulic cylinders as required Replacement or rebuilding pumps motors as required Checking of hydraulic cylinder rod and...