4
2.6. Display Mode
The meter displays
numeric data.
Display mode LCD display of wide-temperature range
Character digits for data item display 8 digits including 6 integers and 2 decimals
Character digits for data ID display 3 digits
2.7. Pulse Constant
Active pulse constant 400 imp/kWh
Reactive pulse constant 400 imp/kvarh
2.8. Active Check Output
The meter is equipped with special pulse indicator for testing active energy (LED is on the
nameplate of meter). In order to ensure the accuracy of active measuring test, according to
different current test points, pulse quantity collected from test should be incremented with the
increase of current, and reasonably select pulses between the numbers 1~8.
2.9. Serial Communication Interface
Interface 1:
Type Baud
Rate
Application
Pattern
Serial bi-direction communication interface
2400 bps
Data reading and related data item configuration
Non-modulated IR communication
Interface 2:
Type Baud
Rate
Application
Pattern
Serial bi-direction communication interface
9600 bps
Data reading and related data item configuration
485 communications
Interface 3:
Type Baud
Rate
Application
Pattern
Serial bi-direction communication interface
9600 bps
MCU and GPRS module communication interface
GPRS Communication
2.10. Meter Electromagnetic Compatibility
No.
Item
Requirements of
IEC62052-11
Meter Standard
1
Electrostatic
Discharge Immunity
Contact
Discharge
8 kV
10 kV
Air Discharge
15 kV
18 kV
2
HF Electromagnetic
Field Immunity
80 MHz-2 GHz
30 V/m
80 MHz-2 GHz
30 V/m
3
Fast Transient Burst
4 kV/100 kHz
4.3 kV/100 kHz
Summary of Contents for SEM 3P V2