SCREW FIXING HOLES
MOTOR WIRE
MIN
MAX
10
30
15
20
–
+
DETAILED VIEW
Only adjust with power switched off
TIMER MIINUTES
PCB BOARD
COVER
POWER
CABLE
ENTRY
1
3 AMP
DOUBLE POLE
FUSED SPUR
_
NEUTRAL
+
LIVE
PULLCORD
SWITCH / LIGHT SWITCH
FIXING CLIP HOLES
MIN
MAX
10
30
15
20
–
+
2 - Yellow - Switched Live
3 - Brown - Permanent Live
1 - Blue - Neutral
1
DIAGRAM X2A
INSTALLATION INSTRUCTIONS FOR THE
TILE FAN RANGE
NOTE:
(i)
For best results this Extractor Fan should be fitted as high on the
wall as possible, or if preferred, on the ceiling.
(ii)
Do not install the unit within a shower cubicle. Use our shower fans.
(iii)
Switch off mains supply before making electrical connections. If in
any doubt contact a qualified electrician.
(iv)
This fan is double insulated and does not require an earth.
(v)
When installing fan through an external wall, an external wall grille
must be fitted at all times.
1.
Cut a suitable diameter hole in the wall. If the fan is to be fixed in the ceiling
ensure that the hole is between the joists.
2.
Hole recommended sizes for plaster board fixing with fixing clips:-
100mm Tile Fan = 115mm, 150mm Tile fan = 173mm and for all other
fixing:- 100mm Tile Fan= 110mm, 150mm Tile Fan=155mm
3.
To remove the front cover from the fan, turn the front cover anticlockwise
while holding the body of the fan steady.
4.
Hold the body of the fan against the wall or ceiling and mark the
four screw holes and the cable entry on the side.(Use the fixing clips
to secure the fan in panel walls & ceilings). See diagram X1A
IMPORTANT: Ensure that the fan is square on wall or ceiling.
5.
Bring power cable into position, as marked. Allow an extra 230mm (9")
protruding to facilitate connection.
6.
Electrical Connection: Standard Model. See Diagram X1.
Remove the internal cover by removing the 2 small caps and retaining
philips screws to access the terminal connections.
The fan can either be operated from a separate pullcord switch fitted to
the ceiling of the room or can be connected to the light switch so that the
fan will start when the light is switched on. A double pole fused spur
having a contact separation of at least 3mm in all poles must be used and
fitted with a 3amp fuse, and should be sited outside any room containing a
shower or fixed bath. The fan should not be accessible to a person using
either the shower or the bath.
NOTE:
All wiring must be fixed securely and the cable to the fan should be
a minimum of 1mm
2
in section. All wiring must comply with current I.E.E.
Regulations. If in any doubt contact a qualified electrician.
077545
02/10
DIAGRAM X2
TIMER MODEL
TOP VIEW
Supplied By APL LTD