7
Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • [email protected]
Chapter 2: Installation and Removal Procedures and Notes
• Installation Notes
•
Mount your
True Echo
TM
series radar
so that it has a clear, perpendicular path to the surface being
monitored. Your sensor should be mounted away from tank or vessel inlets. Do not mount radar in
center of domed tank. (See Figure 2.1)
•
The radar path should be free from obstructions and as open as possible for the 4° off axis beam pat-
tern.
•
If you are using a stand pipe, please see our guide to stand pipes on our website:
http://www.apgsensors.com/about-us/blog/how-to-install-a-stand-pipe
.
•
You should not need any tools to install your
True Echo
TM
series Radar Level Transmitter
. If you are
using a stand pipe to mount your radar, you will probably need tools to install the stand pipe.
• Tools Needed
Figure 2.1
•
Mounting Instructions
Mounting your radar level transmitter is easy if you follow a few simple steps:
•
Never over-tighten the sensor.
•
Always screw in your sensor by hand to avoid cross-threading. Thread failure can be a problem if you
damage threads by over-tightening them or by crossing threads.
IMPORTANT
: Do not over tighten! The sensor should be threaded in only hand tight.