5. OPERATING OF PUMP TERMINAL
BOX
A.Default settings :
Speed 3
= 2850 rpm
Speed 2
= 2400 rpm
Speed 1
= 2000 rpm
Priming speed : = 2850
rpm
Priming time :
= 5 minutes
Adjustable speeds :
1000 - 2850
rpm
in increments of 50 rpm.
Adjustable priming time : 0 to 10 minutes ( by 1 minute steps).
B. User interface :
(A)
Led screen
: displays the engine
speed.
(B)
«SET»
key: accesses the programming
mode or resets the command.
(C)
«1 »
key: selects the fixed speed 1 or
changes it in programming mode.
(D)
«2 / OK»
key selects the fixed speed 2
or saves it in programming mode.
(E)
«3 »
key: selects the fixed speed 3 or
changes it in programming mode.
(F)
«0»
key: Stops the motor.
A
B
F
C
D
E