12
VSD Pump - June 17
-2 additional cable glands are supplied in the housing ref: B01P0232
- In case you use options, they must be added to the case.
To do this, drill the box Ø9mm to put these cables in place.
• Freeze protection
The frost-free thermostat (ref: THG), must be connected directly to the
terminal block (on the right) of the housing (see illustration p.6 ).
The switch-on point (low temperature) must be set on the THG. This
allows the pump to start in V1 so as to prevent from freezing.
To do this, rotate the scroll wheel to the position.
•Lack of water option
This option is composed of a 50 x 1’1 / 2 support collar and a flow sensor.
-The collar is to be positioned on the pipe, at the pump outlet. For this
purpose, the hose must be drilled Ø18mm.
-Screw the sensor in the direction of flow.
-Connect the sensor wire to the terminal block instead of the
shunt.
-The delay in case of absence of flow is 5mn before the stop of the pump.
Drilling of the cable
gland housing.
THG
OME
6.B Added functions on remote box