Fault messages and fault elimination
Message/Symptom
Possible cause
Corrective measures
Display: "- - -“
−
Tool has not been detected
−
Tool defective
−
Check connection of tool to
device
−
Check connected tool
HAP 200 is not working
HAP 200 not connected to
channel 1
Connect HAP 200 to channel 1
Display: "tip"
Soldering tip of microtool not
correctly inserted or defective
−
Insert soldering tip again
−
Replacing defective soldering tip
Pick-up does not stop
−
Vacuum is not fully built up
−
Hose defective or kinked
−
Spring bias too great
−
Check vacuum at pick-up
connection
−
Replace hose
−
Reduce spring bias
No air at HAP
Air hose not or incorrectly
connected
Connect air hose to AIR nipple
No vacuum at unsoldering tool
−
Vacuum hose not or
incorrectly connected
−
Unsoldering nozzle clogged
−
Connect vacuum hose to Vac
nipple
−
Maintain unsoldering nozzle with
cleaning tool
Status indication of VAC LEDs
incorrect
Pressure-gauge level not
correctly set
Set pressure-gauge level in special
menu 2
No display function (display off) No mains supply voltage
−
Turn on mains power switch
−
Check mains supply voltage
−
Check device fuse
VAC LED red
Vacuum system clogged
−
Clean suction nozzle
−
Check filter (13); replace if
yellow
−
Clean unsoldering tool – replace
filter
−
Check vacuum hose