Brief Introduction 

 

Thank you for purchasing  the Apera Instruments  SX811-PW Portable pH Meter kit. This device is an 

outstanding combination of advanced electrical, sensor technology and software design. The meter is 

equipped with LabSen 803 pH Electrode, designed for testing pH levels of purified water such as drinking 

water, RO water, distilled water, deionized water and other low ion-concentration liquid in an accurate 

and convenient manner. It also works well testing regular water solutions. 

 

(for other applications, please refer to Section 11 to find the most suitable electrode)

 

 

1.1 

Features

 

 

This  microprocessor-based  meter  features  automatic  calibration,  automatic  temperature 

compensation  (ATC),  menu  set-up,  calibration  reminder,  calibration  date  checking,  automatic 

powe-off and low-battery warning.

 

 

GLP data management

clock display, manual storage and automatic timing storage, USB port 

and power outage data protection, your data is safe even with a dead battery.   

 

 

Advanced digital processing technology improvs meter responding time and accuracy. 1-3 points 

automatic calibration, calibration guide and self diagnose.

 

 

IP57  waterproof,  operable  under  extreme  conditons.  Powered  by  3  AA  batteries  or  USB 

connection to other power source. Solid and durable case

accessories are included. 

 

 

1.2 

Features of the LabSen 803 Glass pH Electrode

 

 

Proprietary pH sensor technology and materials from Switzerland

 

 

Unique LabSen cylindrical glass membrane, faster response rate, better repeatability in purified 

water

 

 

Get  stable  pH  readings  in  purified  water  or  low  ion-concentration  solutions  in  30  seconds  on 

average. Say goodbye to constant fluctuations

 

 

Patented  pH/Temperature  combination  structure  (Swiss  Patent  Nr.699927),  increasing  the 

temperature respond time by 40% compared to conventional isolated built-in thermistor

 

 

Silver Ion Trap Reference System – On top of the Long-Life reference system, a silver ion trap is 

added to prevent the junction being blocked by silver sulfide, having better stability and longer 

service life.

 

 

Summary of Contents for SX811-PW

Page 1: ...1 SX811 PW Portable pH Meter for Purified Water Instruction Manual APERA INSTRUMENTS Europe GmbH www aperainst de...

Page 2: ...elete 10 4 pH Measurement 11 4 1 Information regarding pH Calibration 11 4 2 pH Calibration use 3 point USA Standard as an example 13 4 3 Customized Calibration 14 4 4 Sample test 15 5 mV measurement...

Page 3: ...n the box 23 9 Warranty 24 10 Appendix I Parameter setup and factory default setup 24 11 Appendix II Abbreviation glossary 25 12 Appendix III Self diagnosis information 25 13 Recommended pH Electrodes...

Page 4: ...e data protection your data is safe even with a dead battery Advanced digital processing technology improvs meter responding time and accuracy 1 3 points automatic calibration calibration guide and se...

Page 5: ...aining in the surface of the movable sleeve which can greatly affect the correct measurement 1 3 2 Usage and Maintenance a Prior to measurement remove the blue rubber plug to maintain proper air press...

Page 6: ...measurement the samples should be abandoned and not be used for its original purpose again g After 1 year of use we recommend replacing the aged electrode to achieve the best accuracy 2 Technical Spe...

Page 7: ...C and RCA 3 Instrument Description 3 1 LCD Display 1 Measurement mode icons 2 Measurement value 3 Timing storage icon When this icon appears the meter is in the automatic storage mode 4 Date and time...

Page 8: ...n when this icon appears the meter connects the computer 17 Low battery icon when this icon appears please renew the battery 3 2 Keypad 3 2 1 Keypad operations Short press 1 5 seconds Long press 1 5 s...

Page 9: ...enu In submenu press this key to enter parameter set up mode In parameter set up mode press this key to confirm parameters Long press In pH measurement mode press and hold this key to change the resol...

Page 10: ...ue 3 4 2 Automatic timing storage Set the storage timing eg 3 minutes from parameter P4 1 icon appears on LCD and the meter enters into the timing storage mode When press key icon flashes and the firs...

Page 11: ...t with clean tissue paper DO NOT rub or wipe the probe just use paper to dap off excess water Unplug the blue rubber plug insert the probe into the test sample gently stir the probe for a few seconds...

Page 12: ...er should be calibrated before test every time For ordinary accuracy measurements 0 1pH once calibrated the meter can be used for about a week or longer In the following cases the meter must be re cal...

Page 13: ...rate the meter End icon appears after calibration is done The 1st point calibration is finished In the meanwhile CAL2 will flash at the upper right corner and 4 00 pH 10 01 pH will flash alternately a...

Page 14: ...y to calibrate the meter After calibration is done LCD at the top right shows blinking CAL2 icon indicating the meter enters into the 2nd point customer defined calibration 3 Rinse pH electrode in dis...

Page 15: ...m parameter setup P1 6 please see Section 6 3 PU 2 icon displays at the right top of LCD please refer to Diagram 11 Note In parameter setup either PU 1 or PU 2 measurement mode can be selected but bot...

Page 16: ...rinciple According to the pH isothermal measurement principle the closer the test sample s temperature is to the calibration solution s the higher the accuracy of the measurement This principle is rec...

Page 17: ...erge the electrode in 0 1mol L dilute hydrochloric acid for 30 minutes then wash it in distilled water then submerge it in the soaking solution for 6 hours b For organic or lipid pollutant clean the p...

Page 18: ...ess key to return to the measurement mode P1 1 Select pH standard solution series P1 2 Set calibration due date P1 3 Check date of last calibration P1 4 Set pH measurement of purified water P1 5 Set p...

Page 19: ...ment of distilled water Off On 1 Press key Off flashes then press key On flashes when parameter flashes press key to confirm Off turn off temperature compensation On turn on temperature compensation 2...

Page 20: ...acklight timing 1 2 3 On 1 When press key 1 flashes then press key to select blinking 2 3 On When the parameter flashes press key to confirm Select On to turn on the backlight the time unit is minute...

Page 21: ...rm Date display Month Date 2 After confirming the parameter press key to enter in P4 8 mode or press key to return to the measurement mode P4 8 Adjust time 1 Press key Hour flashes then press key Minu...

Page 22: ...olved oxygen are classified in the file Export press this key to export the stored value to Microsoft Excel file Exit press this key PC Link program exits from the computer interface 7 3 Load software...

Page 23: ...computer pH and mV are sorted in the program 7 6 Storage during operation During operation press key to store or set timing storage The measuring information is downloaded to the computer through USB...

Page 24: ...rvice for the products purchased by customers not the service life of the tester or probe 10 Appendix I Parameter setup and factory default setup Modes Prompts Parameter setting items Abbreviation Des...

Page 25: ...4 5 Clear readings P4 6 P4 7 P4 8 Others China United States of America NIST Off On No Yes 12 Appendix III Self diagnosis information Icons Self diagnosis information Wrong pH buffer solution or the b...

Page 26: ...ed Water Low ion concentration samples LabSen 803 LabSen 813 Soil LabSen 553 Solid or semi solid samples cheese rice fruit etc LabSen 753 Strong acid samples LabSen 831 MP500 temp probe required Stron...

Reviews: