![Apelson AH60AURC User Manual Download Page 21](http://html1.mh-extra.com/html/apelson/ah60aurc/ah60aurc_user-manual_2952424021.webp)
01
Lamp replacement
The LED lamps in this appliance are not replaceable by the consumer. If a lamp fails, please contact
the customer helpline at the end of Care & maintenance to arrange an engineer visit.
02
Carbon filter replacement
Replace every three months.
3 MONTHS
CARBFILT4
WARNING:
Always switch off the electrical supply before carrying out maintenance work
on the hood. In the event of a fault, contact customer services.
If the motor is off, and after the fan has been in operation for approximately 150 hours, the display
will show and the Timer will flash red to advise you to replace the carbon filters. After replacing
the filters, reset the alert by pressing the Timer
icon.
03
Aluminum grease filter cleaning
To avoid f
i
res, clean thoroughly once a month. To do so, remove the f
i
lters and soak in hot
water and detergent for an hour. If using a dishwasher, position the f
i
lters vertically to improve
the cleaning process.
≤ 65
C
1 MONTH
WARNING:
Increase the f
i
lter cleaning/replacement frequency if the hood is used
for more than 2 hours a day. Always use genuine f
i
lters from the manufacturer.
If the motor is off, and after the fan has been in operation for approximately 50 hours, the display will
s
how
and the Timer will flash red to advise you to clean the aluminum grease filters. After
cleaning the filters, reset the alert by pressing t
he Timer
icon
.
21
2
x
Carbon f
i
lter
s
,
part number 02859394
(
CARBFILT4
)
can be ordered online at
www.spareszone.co.uk
or via the customer
helpline
- see end of Care & maintenance
section for details.
Summary of Contents for AH60AURC
Page 1: ...User Manual Instruction Manual Cooker Hood MODEL UBAHALO6 UBAHALO7 UBAHALO9 AH60AURC ...
Page 2: ... 01 x1 02 x1 03 x1 04 x1 06 x6 05 x6 4 x 32mm 07 x4 3 5 x 10mm 1 2 x2 6mm ...
Page 10: ...04 01 x1 01 05 10 ...
Page 11: ...06 05 07 05 x2 11 ...
Page 12: ...08 75mm 05 03 03 504 733mm 09 05 x2 03 x1 12 ...
Page 13: ...Only for ducted option 04 07 10 09 A A 04 x1 07 x2 11 VENT PACK Ø125mm A 13 ...
Page 14: ...12 A 02 x1 02 CARBFILT4 CARBFILT4 13 B Only for recirculation option B CARBFILT4 14 ...
Page 15: ...14 13 B 02 x1 02 07 15 A B 07 x2 15 ...