9

INSTALLATION

AGHD60GG

instructions provided must install the appliance. The 

manufacturer declines all responsibility for improper 

installation, which may harm persons and animals and 

damage property.

CAUTION

The power supply to the appliance must be switched 

off before any adjustments or maintenance work is 

undertaken.

INSTALLATION OF GAS HOB

WARNING

Good ventilation is required around the appliance for 

easier dissipation of heat and low power consumption.

The gap between the hob and any cooker hood above it 

should be at least 750mm.
The gap between the hob and any adjacent wall cabinet 

above should be at least 450mm.

ELECTRICAL CONNECTION

All installation work must be carried out by a competent 

Before connecting the mains supply ensure that the 

mains voltage corresponds to the voltage on the rating 

plate inside the cooker hood.

WARNING:

THIS APPLIANCE MUST BE EARTHED.

Mains Supply could be connected to the Mains Voltage 

by Direct Connection

WARNING

Make sure the fused spur outlet is 

located in an accessible position.

DIRECT CONNECTION

If the appliance is being connected 

directly to the mains an omnipolar 

circuit-breaker must be installed with a minimum 

opening of 3mm between contacts.
If the cable is damaged or to be replaced, the operation 

dedicated tools to avoid any accidents.
The installer must ensure that the correct electrical 

connection has been made and that it complies with 

wiring diagram.
The cable must not be bent or compressed.
The cable must be checked regularly and replaced by 

authorized technicians only.

ELECTRICAL REQUIREMENTS

Any permanent electrical installation must comply with 

the latest I.E.E. Regulations and local electricity company 

contractor who is on the roll of the National Inspection 

Council for Electrical Installation Contracting (NICEIC) 

should undertake the electrical installation.
Electrical Connection
Before connecting the mains supply ensure that the 

mains voltage corresponds to the voltage on the rating 

plate inside the appliance.

WARNING: 

THIS APPLIANCE MUST BE EARTHED

The appliance is supplied with a 3-core mains cable and 

must be connected to the electricity supply via a double 

pole switch having a 3mm minimum contact gap on each 

connector.

FUSE

USE  A 3 AMP FUSE

DOUBLE POLE SWITCHED

FUSED SPUR OUTLET

ON

75mm

At least
300mm

750mm

At least

300mm

450mm

75mm

At least
300mm

750mm

At least

300mm

450mm

Summary of Contents for AGHD60GG

Page 1: ...AGHD60GG USER MANUAL CUSTOMER CARE 0 44 800 1128 BUILT IN 60CM GAS ON GLASS HOB...

Page 2: ...ead the safety instructions carefully to avoid misuse and hazards Please keep this instruction booklet for future reference and pass it on to any future owners After unpacking the appliance please che...

Page 3: ...rrect installation of this appliance Danger of burns During use the appliance becomes hot Care should be taken to avoid touching heating elements inside the oven WARNING Accessible parts may become ho...

Page 4: ...exercise caution when opening the door Move to side open the door slowly to vent the hot air and or steam Make sure your face is away from the opening and make sure there are no children or pets near...

Page 5: ...trol dial B Rear left control dial C Rear right control dial D Front right control dial YOUR CONTROLS A A Auxiliary burner B Semi rapid burner C Triple ring burner D Hob E Burner caps D Pan supports Y...

Page 6: ...all gas appliances are Installed Serviced by a competent person in accordance with the current editions of the following Standards Regulations Gas Safety Installation Use Regulations Building Regulati...

Page 7: ...essed in for about 10 seconds in order to allow the flame to heat up the thermocouple If the burner goes out when the knob is let go repeat the operation CAUTION If there is no electric current you ca...

Page 8: ...not fixed the flame dividers can be cleaned by simply removing them and washing them with soapy water After drying them well and checking that the holes are not blocked put them back into their correc...

Page 9: ...d directly to the mains an omnipolar circuit breaker must be installed with a minimum opening of 3mm between contacts If the cable is damaged or to be replaced the operation dedicated tools to avoid a...

Page 10: ...following table details the requirements based on the kitchen volume L x W x H in m The above requirements also allow use of a gas oven and grill but if there are any other fuel burning appliances in...

Page 11: ...ices CHECK that the mains supply has not been switched off that the fuse in the spur has not blown that the burner components are not excessively soiled as this can lead to ignition problems that the...

Page 12: ...as a valued customer of Apelson Appliances UK Ltd we will offer you an additional 3 years parts warranty absolutely free If during the extended parts warranty period the appliance fails and it is con...

Page 13: ...ne Email uksupport apelson co uk Web www myspareparts co uk SPARES Apelson Appliances UK LTD Phone 0 800 1128 Email uksupport apelson co uk Web www myspareparts co uk SERVICE AND GUARANTEE Apelson App...

Page 14: ......

Page 15: ......

Page 16: ...APELSON APPLIANCES UK LTD Unit 3 Normandy Landings Pope Street Castleford WF6 2AG...

Reviews: