Item

 

Specifications

 

Liquid handled Type

 

Sewage, waste water, miscellaneous drain water

 

Range

 

Power Supply

 

Material

 

Pump Casing 

EN-GJL-200 

Impeller

 

Enclosed

 

Shaft

 

SUS410 stainless steel

 

Motor type

 

Dry type submersible motor

 

Shaft seal lubrication oil

 

R32 circulation oil

 

10HP (7.5kW) /Three phase / 2 Pole

 

Prior to Operation                                                     

Check the following points upon receipt of your pump: 

Is the pump exactly what you ordered? 

Please confirm by checking nameplate

. It is especially impor-

tant that you check whether the pump is to be used with

 50 or 60 Hz.

 

Has any damage occurred during shipment? Are any bolts or nuts loose? 
Have all necessary accessories been supplied? (For a list of standard accessories please see 

Con-

struction page.8

 

We recommend that you keep a spare pump on hand in case of emergencies. Keep this instruc-
tion manual in a place for future reference. 
                                                                        
Check the nameplate for your pump’s head (Hmax), volume (Qmax), speed (R.P.M), motor volt-
age and current. 

Other specifications are noted in the chart as below. 

 

Summary of Contents for SSDM-10HP Series

Page 1: ...SSDM 10HP Series Installation and operation manual...

Page 2: ...2...

Page 3: ...ny way other than as described in this instruction manual especial on WARNING After reading this instruction manual keep it nearby as a reference in case questions arise during use If this instruction...

Page 4: ...ordered Please confirm by checking nameplate It is especially impor tant that you check whether the pump is to be used with 50 or 60 Hz Has any damage occurred during shipment Are any bolts or nuts l...

Page 5: ...uld cable be pulled while the pump is being transported or installed Attach a chain or rope to the grip and install the pump This pump must not be installed on its side or operated a dry condition Ens...

Page 6: ...A If the cable is extended do not immerse the splice in water B Fasten the cable to the discharge piping with tape or vinyl strips C Install the cable so that it will not overheat Overheating caused...

Page 7: ...clogging the pump If the quantity of liquid discharged falls suddenly foreign matter may be blocking the suction inlet 2 Regular inspections a Monthly inspections Measure the insulation resistance Th...

Page 8: ...8 Construction SSDM 10HP...

Page 9: ...r Casing SUS304 35 Socket Screw SUS304 12 Motor Frame A356 36 Screw Flat Washer SUS304 13 Discharge Gasket NBR 37 Headless Socket Screw Nut SUS304 14 Outer Casing Gasket NBR 38 Phillips Screw SC 15 Up...

Page 10: ...Correct rotation Does not pump Inadequate vol ume 1 Reverse rotation 1 Correct rotation see Operation 2 Significant drop in voltage 2 Contact electric power company 3 Operating a 60Hz pump with 50Hz 3...