Troubleshooting  

Trouble

 

Cause

 

Remedy

 

Does not start. 
Starts, but imme-
diately stops. 

(1) Power failure 

(1)~(3) Contact electric power company and 
devise counter-measures 

(2) Large discrepancy between power source and voltage 

(3) Significant drop in voltage 
(4) Motor phase malfunction 

(4) Inspect electric circuit 

(5) Electric circuit connection faulty 

(5) Correct wiring 

(6) Faulty connection of control circuit 

(6) Inspect connections and magnetic coil 

(7) Fuse is blown 

(7) Check circuit then replace fuse 

(8) Faulty magnetic switch 

(8) Replace with correct one 

(9) Water is not at level indicated by Float 

(9) Raise water level 

(10) Float is not in appropriate level 

(10) Adjust the position of float 

(11) Float is not effective 

(11) Repair or replace 

(12) Short circuit breaker is functioning 

(12) Repair location of short circuit 

(13) Foreign matter clogging pump 

(13) Remove foreign matter 

(14) Motor burned out 

(14) Repair or replace 

(15) Motor bearing broken 

(15) Repair or replace 

Operates, but 
stops after a 
while. 

(1) Prolonged dry operation has activated motor protector 

and caused pump to stop 

(1) Raise water level to C.W.L 

  

(2) High liquid temperature has activated motor protector 

and caused pump to stop 

(2) Lower liquid temperature 

(3) Reverse rotation 

 ! WARNING :

 (3) 

Correct 

rotation 

Does not pump. 
Inadequate vol-
ume. 

(1) Reverse rotation 

(1) Correct rotation (see Operation) 

(2) Significant drop in voltage 

(2) Contact electric power company 

(3) Operating a 60Hz pump with 50Hz 

(3) Check nameplate 

(4) Discharge head is high 

(4) Recalculate and adjust 

(5) Large piping loss 

(5) Recalculate and adjust 

(6) Low operating water level causes air suction 

(6) Raise water level or lower pump 

(7) Leaking from discharge piping 

(7) Inspect, repair 

(8) Clogging of discharge piping 

(8) Remove foreign matter 

(9) Foreign matter in suction inlet 

(9) Remove foreign matter 

(10) Foreign matter clogging pump 

(10) Remove foreign matter 

(11) Worn impeller 

(11) Replace impeller 

Over current 

(1) Unbalanced current and voltage 

(1) Contact electric power company 

(2) Significant voltage drop 

(2) Contact electric power company and 

devise counter-measure 

(3) Motor phase malfunction 

(3) Inspect connections and magnetic 

switch 

(4) Operating 50Hz pump on 60Hz 

(4) Check nameplate 

(5) Reverse rotation 

 ! WARNING :

 

(5) Correct rotation (see Operation2) 

(6) Low head. Excessive volume of water 

(6) Replace pump with high head pump 

(7) Foreign matter clogging pump 

(7) Remove foreign matter 

(8) Motor bearing is worn out or damaged 

(8) Replace bearing 

Pump vibrates; 
excessive oper-
ating noise. 

(1) Reverse rotation 

(1) Correct rotation 

(2) Pump clogged with foreign matter 

(2) Disassemble and remove foreign matter 

(3) Piping resonates 

(3) Improve piping 

(4) Strainer  is closed too far 

(4) Open strainer 

Summary of Contents for SSDM-10HP Series

Page 1: ...SSDM 10HP Series Installation and operation manual...

Page 2: ...2...

Page 3: ...ny way other than as described in this instruction manual especial on WARNING After reading this instruction manual keep it nearby as a reference in case questions arise during use If this instruction...

Page 4: ...ordered Please confirm by checking nameplate It is especially impor tant that you check whether the pump is to be used with 50 or 60 Hz Has any damage occurred during shipment Are any bolts or nuts l...

Page 5: ...uld cable be pulled while the pump is being transported or installed Attach a chain or rope to the grip and install the pump This pump must not be installed on its side or operated a dry condition Ens...

Page 6: ...A If the cable is extended do not immerse the splice in water B Fasten the cable to the discharge piping with tape or vinyl strips C Install the cable so that it will not overheat Overheating caused...

Page 7: ...clogging the pump If the quantity of liquid discharged falls suddenly foreign matter may be blocking the suction inlet 2 Regular inspections a Monthly inspections Measure the insulation resistance Th...

Page 8: ...8 Construction SSDM 10HP...