background image

E-RM 30

 Installation and service manual

 M2016/09f[EN] 

3. C

ONSTRUCTION

 

AND

 

TECHNICAL

 

DATA

3.1. T

ECHNICAL

 

DATA

Environment temperature

5 to 50 °C

Billing period

e.g. chapter 2.1. Type list

Calendar functions

month consumption, 12 months history (standard flow and backflow)

Data reading

radio and infra-red interface

Protection against cheating

backflow detection for example, reversal of the meter

electronic seal – records the data of any manipulation or removal of 
device

magnetic pole deletction (> 3 mT) – only E-RM 30.3**

an option to mechanically lock the radio module to the water meter

Backup data

daily backup of measured values including real time

Function control

automatic

 Dimensions

70 x 44 x 71 mm

Power suply

 lithium battery 3 V

Calculat. battery lifetime

e.g. chapter 2.1. Type list

Material

polycarbonate

IP code

IP64

Class of climate and 
mechanical environment

B

Class of electromagnetic 
environment

E1

Working frequency

868 MHz

Transmitting wattage

< 5 mW

Class of operating cycle

1 (percent of operating cycle <0,1 %)

Length of transmission

< 8 ms

 Transmission frequency

E-RM 30.**1 (year billing period)

60-66 seconds first month after beginning of billing period

240-246 seconds rest of the year

E-RM 30.**2 (month billing period)

60-66 seconds first 3 days after beginning of billing period

240-246 seconds rest of the year

Transmition 

up to 500 m (with standard antenna, reading carried out by antenna 
ZZ P- 868

5 / 17

Summary of Contents for E-RM 30

Page 1: ...RADIO MODULE FOR WATER METER E RM 30 Installation and service manual APATOR METRA s r o Havl kova 919 24 787 64 umperk tel 420 583 718 111 fax 420 583 718 150 e mail prodej metra su cz www http www m...

Page 2: ...mode 9 5 3 2 Switch a radio module to the mode of automatic activation 9 5 3 3 Switch a radio module to the sleeping mode 10 5 4 Electronic seal reactivation 10 6 OTHER INFORMATIONS 10 6 1 Transportin...

Page 3: ...are also used data are read simultaneously Every user can control current value on analogue dial of water meter In contrast to the traditional water meter radio module E RM 30 distinguish the directio...

Page 4: ...dio module is equipped with electronic seals and also the option to use mechanical seals in order to safeguard the module from tampering If there is an unauthorised removal of the module from the mete...

Page 5: ...of measured values including real time Function control automatic Dimensions 70 x 44 x 71 mm Power suply lithium battery 3 V Calculat battery lifetime e g chapter 2 1 Type list Material polycarbonate...

Page 6: ...ion in past billing period back flow consumption in billing period before last standard flow consumption in billing period before last back flow date of electronic seal activation date of electronic s...

Page 7: ...n consists only from putting module on water meter and installation of mechanical seal In mode of automatic activation module regulary tests disc presence If the presence is detected measuring of wate...

Page 8: ...reading unit IRU 10 00 The IRU 10 00 displays information related to the last unit it has read It is therefore necessary to carry out a data reading from the radio module so that you can view the par...

Page 9: ...l mode change is indicated by a single beep and the display showing o Pro 5 An unsuccessful mode change is indicated by four beeps and the display showing E Pro For more informations refer to the Inst...

Page 10: ...adio module is now in working mode and has broken electronic seal 2 Cover optical sensors with black cover used during module trasportation 3 Switch a radio module to the sleeping mode with an infra r...

Page 11: ...ntrary to installation and service manual or damaged during transport or storage by customer or reseller when mounted or dismantled to the customer device because of improper handling or installation...

Page 12: ...E RM 30 Installation and service manual M2016 09f EN 12 17 Illustracion 3 Packing sheet...

Page 13: ...et of water which pushes ifs blades along the vane perimeter and it is the only movable element submerged in water Rotor rotation is conveyed by a magnetic head clutch through the sealing plate Dry co...

Page 14: ...ion notified person number flow direction as an arrow V or H marking for vertical or horizontal pipes or both jet flow value Q3 Q1 andr Q3 ratio marking of measurement unit in m3 on the counter dial v...

Page 15: ...k between a valve and a strraight pipe section and before the water meter 5 For an installation of a water meter which does not cause strain in the body it is recommended to use compensative connector...

Page 16: ...tion and the filter if it is used should be cleaned During flushing use a spigot to replace the water meter 2 Before installation check the operation of a water meter by starting a rotating motion of...

Page 17: ...alternative connector JS 90 2 5 G1 8 3 WATER METER GSD8 RF Nominal flow Qn 1 5 m3 h Maximal flow Qmax 3 m3 h Max working pressure 16 bar Class of accuracy B horizontal installing A vertical installing...

Reviews: