Instruction manual
REVAMP1680
9
5. Power on mode selector: power on:
the amplifier is powered
on when the power switch at the front panel is switched to
the on position. In the Audio Trig position, the amplifier will be
switched on automatically when a strong audio signal is present
at the input. In the Ext Trigger position, you have to apply a
3-30 V AC or DC voltage at the jack input “6”. The power
switch on the front panel must be in the on position. In the off
position, the amplifier will always be off.
6. Trigger input jack:
3.2 mm monojack input for the 3-30 V AC
or DC trigger voltage. The trigger voltage will switch on the
amplifier when switch “5” is in the Ext Trigger position and the
front panel power switch is in the on position.
7. Ext Trigger output jack pass through (out) connector, 3.2 mm
mono minijack:
the trigger voltage applied at connector “6” is
passed through via this connector.
8. Channel input gain setting
. Adjust the input gain to the output
level of your source.
9. Amplifier mode selector:
set to stereo for normal operation, set
to bridge for bridged mode. Load impedance in bridged mode
must be 8 ohms or higher.
10. Input selector for zone 1
. Select Bus 1, Bus 2 or Line in.
11.
Zone 1 stereo speaker outputs on euroblock
. Minimum load
impedance is 4 ohms in stereo mode and 8 ohms in bridge
mode.
12.
Line in:
unbalanced stereo input on RCA connector. In bridge
mode: use left input only.
13. Mains inlet connector:
connect the mains cable supplied with
Summary of Contents for REVAMP1680