1.

In order to ensure the good performance of the product, the fan should be cleaned and maintained in time according to the use environment

 

and the required electrostatic protection requirements, that is, using electrostatic brush, dust-free cotton swab, dust-free cloth dipped in

 

anhydrous alcohol to gently remove the dust on the electrode, discharge bracket, fan and metal mesh cover. Note:

A

A.. Operation must be done 10 minutes after power cut of

B. The cleaning cycle of the electrode needle should be set according to the working environment during use of the fan. It should be

appropriately reduced in the environment with more humid and dusty.

CC.. The fan must be powered on after alcohol is completely volatilized after cleaning. No other organic solvent can be used to clean the fa

D. The alloy electrode is a consumable product which is not included in the scope of warranty and will be charged for replacement when

repairing.

2. Do not press or rotate the control buttons on the fan panel too hard; otherwise, the device will be permanently damaged.

3. If the working indicator light on the front panel of the fan is off or red, it should be stopped and repaired by professional maintenance

personnel. It can be used only after the electrical performance index is normal.

Maintenance

After-sales service

AP-DJ

28

3X

 

series DC 

ionizing air blower has undergone rigorous testing and aging treatment before ex-work. Its performance has completely 

reached the relevant indicators marked in the usage instruction.

AP&T makes a commitment to the customer that any defective parts inspected by AP&T will be repaired or replaced free of charge within one 

year from the date of purchase. However, this commitment does not apply to:

1.  The device is incorrectly used or installed.

2.  Damage caused by negligence or accident during use;

3. Modified, disassembled or repaired by other service departments not authorized by Anping Company.

AP&T assumes no obligation or liability to the user of the product except for the repair or replacement of the part as set forth herein.

Summary of Contents for AP-DJ283 Series

Page 1: ...Intelligent Static Removal High speed Self balancing LCD Display Shanghai Anping Static Technology Co Ltd AP DJ283X IONIZING AIR BLOWER...

Page 2: ...Multi models available Suitable for different production environments AP DJ2832 AP DJ2831 AP DJ2834 AP DJ2833 Durable Intelligent remote control Network monitoring One button start CE certification...

Page 3: ...removal Prevent adhesion of objects Prevent material splash Prevent static electricity Prevent blockage of feeder Industry Application Widely used in electronics optoelectronics and semiconductor indu...

Page 4: ...he working status of ionizing air blower online Wireless communication IMS monitoring software Network Monitoring AP DY6703 AP KT3701 AP DY6704 USB wire link USB wire link IMS monitoring software IMS...

Page 5: ...Button Function instructions Unlock Run Pause Clean Adjust clean time Adjust air volume Adjust ion balance Confirm Reset Unlock before adjusting operating parameters 30s delay if any key is pressed ex...

Page 6: ...re negative ions output to neutralize the excess positive charge on the surface of the object Increase Tp so that the positive voltage acting capacity becomes greater and the acting time becomes longe...

Page 7: ...ibution diagram of AP DJ2831 Discharge time distribution diagram of AP DJ2831 Keep a clean production environment and stay away from static electricity High Efficiency Static Removal Test Height mm Di...

Page 8: ...scharge speed within 2 5 sec when vertical installation distance is 450mm Discharging distance Up to 1050mm width Keep a clean production environment and stay away from static electricity High Efficie...

Page 9: ...fan five speed adjustment Stable performance and air volume output 1 45 times higher than ordinary fans Built in cleaning brush Automatic needle brushing function when start up By default the needle...

Page 10: ...reliability static eliminator Ion self balance function The self balance range is 10V and the balance voltage can be displayed in real time Intelligent remote control The negative high voltage amplit...

Page 11: ...Power switch Air volume adjustment LCD display Status Indicator Front Front Back Back AP DJ2832 2833 2834 AP DJ2831 Bakelite screw handle M5 8 Front cover Back cover L shaped bracket Three in one pow...

Page 12: ...to 4 air outlets Balance voltage of the air outlet Temperature of the current operating environment Humidity of the current operating environment Cleaning indication Fan fault alarm High voltage fault...

Page 13: ...orking humidity 70 RH Dimensions L W H Fan body size 142 70 5 190mm 510 154 70mm 760 154 70mm 1011 154 70mm Shell material Aluminum powder spraying Installation accessories 1 pair of L shaped iron pow...

Page 14: ...0 154 192 70 154 760 786 125 250 250 125 77 750 192 154 77 1011 1037 70 1000 125 250 250 250 125 192 49 13 30 65 150 165 2 R6 1 5 8 5 Installation accessories 1 pair of U shaped aluminum powder sprayi...

Page 15: ...Installation steps Technical tips 1 Place the ionizing air blower in the work area where static electricity is to be eliminated and the installation angle is perpendicular to the surface of the charge...

Page 16: ...or on the fan panel is off The electrostatic removal performance decreased obviously The electrostatic removal performance decreased High voltage ion balance alarm Panel indicator light flashes red Fa...

Page 17: ...ing 2 Do not press or rotate the control buttons on the fan panel too hard otherwise the device will be permanently damaged 3 If the working indicator light on the front panel of the fan is off or red...

Page 18: ...g analysis and elimination solution provider Speciality Creates Value AP T Shanghai Anping Static Technology Co Ltd Tel 86 21 64517676 Fax 86 21 64517673 Postcode 200233 Website www ap static com Addr...

Reviews:

Related manuals for AP-DJ283 Series