Power interface cable function information
1
、
2
3
4
5
6
7
8
9
The output wiring diagrams of pins 7 and 8 are as follows:
RUN/STOP
A00
S4
T04
F2 F1
+07 -08
28
℃
62%RH
Cleaning...
Fan Fault!!!
HV Warning!!!
LCD display parameters
Display content
Description
Sample graph
LCD parameter display description
Run / Pause
Working address of the device
:
00
The current wind speed gear: 4 (5 gears in total,
wind speed in gear 1 is the largest)
Cleaning cycle
:
04
(
Unit
:
H
)
The current air outlet of the device
(
AP-DJ28 series ionizing air blower have 1 to 4 air outlets
)
Balance voltage of the air outlet
Temperature of the current operating environment
Humidity of the current operating environment
Cleaning indication
Fan fault alarm
High voltage fault alarm
Green light
:
Running
Blue light
:
Pause / Standby
Blue light flashes
:
Cleaning
Red light
:
Fan fault alarm
Red light fashes
:
HV alarm
VCC
:
+24VDC
RS485+B
RS485+A
GND
GND
PE
Orange/White-orange
Blue
White-blue
Green
White-green
Brown
VTH
:
Sensor threshold alarm
HVAL
:
Eliminator high voltage alarm
White-brown
Clean
:
Eliminator cleaning indication
Metal shield
ACT
:
Sensor/eliminator power-on indication
HV Alarm signal:Normal--always
open
、
Abnormal--always close
Power signal :Normal--always close
cleaning signal
:Clean--always open