background image

No.1

No.3

No.4

Magnetic net cover

The power is cut off immediately and the fan is in 

the standby (STOP) state when the net cover is 

separated , which is convenient for disassembly 

and maintenance.

Built-in cleaning brush

Automatic needle brushing function when start 

up. By default, the needle is automatically 

brushed every 4 hours for manual cleaning and 

maintenance free.

Fault alarm

Display screen show fault alarm and LED red 
light alarm when the fan, ion balance, and high 
voltage breakdown.

No.5

Network Monitoring

Wired network communication realisable 

and monitor the working status of the air 

blower.

RS485

communication

IMS monitoring software

No.2

High air volume fan five 

speed adjustment

Stable performance and air volume output 
1.45 times higher than ordinary fans.

Features

Safe / Easy to use / Durable

Summary of Contents for AP-DJ2812

Page 1: ...Intelligent Control Network LED Display Ionizing Air Blower AP DJ2812 Shanghai Anping Static Technology Co Ltd AP TR AP T New Product Intelligent Control Network LED Display Ionizing Air Blower ...

Page 2: ...ems caused by static electricity Suitable for electronics optoelectronics semiconductor and other industries Static removal Prevent blockage of feeder Prevent static electricity Prevent material splash Prevent adhesion of objects ...

Page 3: ...oring Monitoring the working status of ionizing air blower online RS485 communication AP DY6703 AP KT3701 AP DY6704 USB wire link USB wire link IMS monitoring software IMS monitoring software IMS monitoring software ...

Page 4: ... Button Function instructions Unlock Run Pause Clean Adjust clean time Adjust air volume Adjust ion balance Confirm Reset Unlock before adjusting operating parameters 30s delay if any key is pressed exit and re locked if no key is pressed Device starts running when power is on Press STOP to standby and no high voltage output Press RUN again and the device will start working Press the button to cle...

Page 5: ... of the object Increase Tp so that the positive voltage acting capacity becomes greater and the acting time becomes longer More positive ions and less negative ions output to neutralize the excess negative charge on the surface of the object Adjust the duty ratio Tp Tp Tn to an appropriate ratio and send out the same amount of positive and negative ions to neutralize the static electricity on the ...

Page 6: ...onment and stay away from static electricity High Efficiency Static Removal Ion balance distribution diagram of AP DJ2812 Discharge time distribution diagram of AP DJ2812 Test Height mm Discharge Time s Test Length mm Ion Balance V Test Length mm Test Height mm Note The 0 point of the test length is the center position of the air blower Test standard ANSI ESD STM3 1 SJ T 11446 2013 Test instrument...

Page 7: ...lly brushed every 4 hours for manual cleaning and maintenance free Fault alarm Display screen show fault alarm and LED red light alarm when the fan ion balance and high voltage breakdown No 5 Network Monitoring Wired network communication realisable and monitor the working status of the air blower RS485 communication IMS monitoring software No 2 High air volume fan five speed adjustment Stable per...

Page 8: ...ncing function The self balancing range is 10V and the balance voltage can be displayed in real time Intelligent remote control The negative high voltage amplitude is adjustable which can be used to adjust the ion balance voltage Ion output characteristics can be adjusted by remote control 10V No 6 LED display LED display shows the equipment address e g A00 wind speed gear e g S1 cleaning cycle e ...

Page 9: ...et 28 Temperature of the current operating environment 62 RH Humidity of the current operating environment Cleaning Cleaning indication Fan Fault Fan fault alarm HV Warning High voltage fault alarm Green light Running Blue light Pause Standby Blue light flashes Cleaning Red light Fan fault alarm Red light fashes HV alarm Product Use Panel functions specification dimensions Power interface cable fu...

Page 10: ...acket 2 60KG 1Year CE Specification Installation accessories 1 pair of L shaped aluminum powder spraying mounting brackets 1 pair of bakelite screw handles M5 8 Unit mm Dimensions 510 536 77 125 250 125 500 70 154 192 49 13 30 通 65 150 165 2 R6 1 5 8 5 Model Input voltage Input voltage Output voltage Power Ion emission Emitter electrode Discharge range Air volume Noise Ozone thickness Ion balance ...

Page 11: ... 8YXG25110 1 8WXI00004 1 AP2253011 1 Products Use Installation steps technical tips Packing accessories 1 Place the ionizing air blower in the work area where static electricity is to be eliminated and the installation angle is perpendicular to the surface of the charged body 2 Ionizing air blower should be at least 300mm away from the metal conductor and metal grounding body The ionizing air blow...

Page 12: ...g Faults The indicator on the fan panel is off The electrostatic removal performance decreased obviously The electrostatic removal performance decreased High voltage ion balance alarm Panel indicator light flashes red Fan alarm Panel indicator red light always on Unable to discharge The display is off or flickering The product is smoky or burnt Reasons Solutions Trouble shooting Poor contact of th...

Page 13: ...n repairing 2 Do not press or rotate the control buttons on the fan panel too hard otherwise the device will be permanently damaged 3 If the working indicator light on the front panel of the fan is off or red it should be stopped and repaired by professional maintenance personnel It can be used only after the electrical performance index is normal Maintenance After sales service AP DJ2812 ionizing...

Page 14: ...nitoring analysis and elimination solution provider Speciality Creates Value AP T Shanghai Anping Static Technology Co Ltd Tel 86 21 64517676 Fax 86 21 64517673 Postcode 200233 Website www ap static com Address 3 F Building 27 No 69 Guiqing Road Shanghai China ...