Shanghai Anping Static Technology Co,.LTD
www.ap-static.com
2) The area around the ionizing air blower should be at least 30cm away from the metal conductor and metal
ground.
3) The ionizing air blower should be more than 20cm away from obstacles such as walls.
The air inlet is at least 15cm from the wall.
4.Failure solution:
NO
.
Problems
Possible reason
Solution
1
Fan panel indicator is off
Poor power cord connection
Check whether the power cord
is intact and connected firmly
Power supply voltage mismatch
INPUT
:
220VAC 50Hz
2
Significantly reduced static
elimination performance
Discharge needle contamination and
damage
Clean or replace the discharge
needle
The orientation of the ionizing blower
is incorrect
Confirm the best installation
position
3
Reduced static elimination
performance
There is a conductor or other ion fan
around the ionizing air blower
Remove (moving) conductors
or other ion fans
5
Unable to discharge
High voltage module is damaged
Return to factory
Motherboard chip is damaged
Return to factory
6
Product smokes or burns
Burnout of main control board
components
Return to factory
Maintenance
1. In order to ensure the good performance of the product, the fan should be cleaned and maintained in a timely
manner according to the use environment and the required electrostatic protection requirements, that is, use an
electrostatic brush, a dust-free cloth dipped in absolute alcohol to gently remove the discharge electrode and metal
Carbon deposits on the grille. Note:
A. It must be operated 10 minutes after the power is turned off.
B. When the fan is in use, when the needle tip is dusty or white, it must be cleaned.
C. After cleaning, you must wait for the alcohol to completely evaporate before powering on. You cannot use
any other organic solvents to clean the fan.
D. Alloy electrodes are consumables and are not covered by the warranty. The company has to charge for