background image

2. Filter Duct Installation Instructions

PNEG-1608

 Pathogen Barrier Filter Ducts

9

Filter Duct Frame-Out for 6 Filters

1. Frame out the area for the duct (A) between the truss cords, making sure that the frame (D) is flush 

with the top. 

(See Figure 2C.)

2. Install the attic vent (G) according to the attic vent installation instructions. 

(See Figure 2A on Page 7.)

3. Fill in the area around the hole cut for the vent (G) with insulation (C).

4. Cut a sheet of plywood (B) for XX" x 48-3/4", that should fit on the top of the truss frames (D).

NOTE:

 

Width 48-3/4" is measured from the middle of truss to truss and the length XX" is based 

on the customer.

5. Cut a hole in the plywood (B) the same dimensions as the vent (G) and at the same location within 

the truss frame (D), so that the hole aligns with the vent (G) when the plywood (B) is installed.

6. Apply caulking (F) along the top of the frames (D) where the plywood (B) will be installed and install 

the plywood (B).

7. Apply caulking (F) on top of the plywood (B) where the duct (A) will be installed and install the duct (A).

Figure 2C Filter Duct Frame-Out - 6 Filters

Ref #

Description

Ref #

Description

A

Filter Duct

E

Ceiling

B

Plywood

F

Caulking

C

Insulation

G

Attic Vent

D

Frame-Out

Assembly view

78-1/4"

48-3/4"

D

B

C

E

G

F

F

A

Summary of Contents for PNEG-1608

Page 1: ...PNEG 1608 Pathogen Barrier Filter Ducts Installation Manual PNEG 1608 Version 3 0 Date 06 12 19...

Page 2: ...ier Filter Ducts All information illustrations photos and specifications in this manual are based on the latest information available at the time of publication The right is reserved to make changes a...

Page 3: ...ilter Ducts 8 Filter Duct Frame Out for 6 Filters 9 Filter Duct Frame Out for 8 Filters 10 Filter Duct Assembly 11 Filter Duct Installation 15 Filter Installation 16 Chapter 3 Parts List 17 Filter Duc...

Page 4: ...a at all times Alterations shall not be made to the equipment Alterations can produce dangerous situations resulting in SERIOUS INJURY or DEATH This equipment shall be installed in accordance with the...

Page 5: ...This symbol indicates an imminently hazardous situation which if not avoided will result in serious injury or death This symbol indicates a potentially hazardous situation which if not avoided can re...

Page 6: ...ack ST 0004 1 Follow Safety Instructions Carefully read all safety messages in this manual and safety signs on your machine Keep signs in good condition Replace missing or damaged safety signs Be sure...

Page 7: ...27 1 2 x 43 1 2 3 Add 2 x 4 filler boards D against the inlet side of both lower truss cords E flush to the top attic side See Figure 2A 4 Install insulation F into the dead space between the frame o...

Page 8: ...d 50 x 19 1 2 for the 2 filter duct F NOTE It is recommended to center the filter duct after the inlet 3 Add 2 x 4 filler boards E against the inlet side of both lower truss cords D flush to the top a...

Page 9: ...D NOTE Width 48 3 4 is measured from the middle of truss to truss and the length XX is based on the customer 5 Cut a hole in the plywood B the same dimensions as the vent G and at the same location wi...

Page 10: ...s D NOTE Width 48 3 4 is measured from the middle of truss to truss and the length XX is based on the customer 5 Cut a hole in the plywood B the same dimensions as the vent G and at the same location...

Page 11: ...flange length is covered 2 Continue to assemble the filter B and end panels C with the screws E provided 3 Apply one strip of caulk D completely around the top flange of the filter panels B 4 Apply ex...

Page 12: ...r Filter Ducts Figure 2F Filter Duct with 2 Filters 30 0662 Exploded View Figure 2G Filter Duct with 4 Filters 30 0664 Exploded View Ref Description Ref Description A Top Panel E Screws B Top Filter P...

Page 13: ...Instructions PNEG 1608 Pathogen Barrier Filter Ducts 13 Figure 2H Filter Duct with 6 Filters 30 0666 Exploded View Ref Description B Top Filter Panel C End Panel E Screws G Round Knurled Knob H Side...

Page 14: ...tallation Instructions 14 PNEG 1608 Pathogen Barrier Filter Ducts Figure 2I 2 Filter Duct 30 2402 Exploded View Figure 2J 3 Filter Duct 30 2403 Exploded View Ref Description B Top Filter Panel C End P...

Page 15: ...the wood frame out B with silicon caulk See Figure 2A on Page 7 2 Apply an ample amount of silicon caulk around the top side of the filter duct frame out 3 Set the filter duct A on the frame out B and...

Page 16: ...provided 2 Place the L6 L9 barrier filters through the opening s allowing them to rest on the bottom filter retainer bracket s Note the direction of the clips on the filters See Figure 2L 3 Install th...

Page 17: ...ith 2 Filters 30 0662 See Page 18 2 Filter Duct with 4 Filters 30 0664 See Page 19 3 Filter Duct with 6 Filters 30 0666 See Page 20 4 Filter Duct Top Load 6 Pathogen Barrier Filters 30 1000 See Page 2...

Page 18: ...24 x 24 M14 L6 Sealed Pathogen Barrier With Gasket on Header 1 5 S 9423 Screw SMSAB 12 x 5 8 HWH ZN 65 6 30 0667 Filter Retaining Bracket Assembly 4 7 S 9424 Round Knurled Knob 1 4 20 x 1 2 SS 12 8 3...

Page 19: ...1 4 30 0655 24 x 24 M14 L6 Sealed Pathogen Barrier with Gasket on Header 2 5 S 9423 Screw SMSAB 12 x 5 8 HWH ZN7 72 6 30 0667 Filter Retaining Bracket Assembly 4 7 S 9424 Round Knurled Knob 1 4 20 x 1...

Page 20: ...0655 24 x 24 M14 L6 Sealed Pathogen Barrier with Gasket on Header 3 5 S 9424 Round Knurled Knob 1 4 20 x 1 2 SS 18 6 S 9423 Screw SMSAB 12 x 5 8 HWH ZN 88 7 30 0550 High Capacity V Style Filter 95 Dop...

Page 21: ...Ref Part Description Qty 1 30 0660 Side Panel 2 2 30 1002 6 Filter Top Panel Assembly 1 3 30 1001 Filter Duct End Panel 6 Filter 2 4 30 0927 Filter Turn Clamp 4 5 30 1032 Filter Clamp Bracket 4 6 S 1...

Page 22: ...rrier Filter 30 1011 Ref Part Description Qty 1 30 0660 Side Panel 2 2 30 1010 8 Filter Top Panel Assembly 1 3 30 1009 Filter Duct End Panel 8 Filter 2 4 30 0927 Filter Turn Clamp 6 5 30 1032 Filter C...

Page 23: ...on behalf of a claimant without prior written authorization from the GSI warranty department shall not be reimbursed This warranty is not transferable and applies only to the original end user GSI sh...

Page 24: ...n codes and applicable regulations which should be carefully followed in all cases Authorities having jurisdiction should be consulted before installations are made 1004 E Illinois St Assumption IL 62...

Reviews: