background image

6  

 

I. SOLDERING IRON HOLDER

 

1.   Dampen the cleaning sponge with water, squeeze it dry and place 
it in its base.  

II. 

SOLDERING IRON STAND

 

 
 
 
 
 

 

 

 

 

 

 

 

 

 

III. SOLDERING IRON / TWEEZERS

 

1.  Attach the soldering iron or tweezers to the receptacle connector 

at the bottom right area of the main unit.  

2. 

Place soldering iron or tweezers to the soldering iron stand.

 

IV. MAIN UNIT CONTROLS

 

1.  Plug the power cord into a receptacle with ground. 

 

 

 

 

 

ASSEMBLY INSTRUCTIONS  

 

Heater 

Calibration Point 

Main 

power 

Temperature 

adjustment knob 

Hand 
piece  

Power 

11  

 

 

TROUBLESHOOTING CONNECTIONS 

The 5 pin socket can be tested to detect faults in the  hand piece: 

Before  plugging  in  the  hand  piece  conduct  the 
continuity test as shown:

 

 

If  any  of  the  combination  registers  a  short 

review the steps in “replacing the heating element” 
to ensure proper connections.

 

Pins 4 & 2 

 

Pins 4 & 1 

 

Pins 5 & 1 

 

Pins 5 & 2 

 

Warning: Ensure none of the above mentioned conditions are 

present before plugging in the hand piece. Failure to do so can 
damage the internal circuitry of the unit.

 

Follow the following direction to test for hand piece cord 
faults: 

 

Test 1: Rendering physical strain to the cord 

1.  Turn on the unit. 
2.  Set  temperature to 480 °C. 
3.  Bend and straiten the entire length of the cord bit by bit. The 

heater lamp should always be lit while doing so. If the heater 
lamp  becomes  intermittent  the  cord is  faulty  and  should  be 
replaced. 

 
 
 
 

Test 2: Resistance  test 

1.  Follow the steps in disassembling the hand piece . 
2.  Test for continuity between the pins and colored wires at the hand 

piece PCB, all matching contacts at the PCB and wires should 
register 

 to 2 

 

Note: the Heater lamp will blink if the temperature of the soldering iron tip has 

reached the set temperature i.e. 480°C. this is not an indication of a faulty cord. 

Summary of Contents for Int950

Page 1: ...therefore be careful when using the appliance in places where there are combustible materials do not apply to the same place for a long time do not use in presence of an explosive atmosphere be aware...

Page 2: ...2 15 REPLACEMENT SOLDERING TIPS...

Page 3: ...on how to clean soldering tips Temperature could be set too high causing solder to quickly burn away Please adjust to a more suitable lower temperature range PROBLEM 5 SOLDERING IRON DOES NOT PRODUCE...

Page 4: ...rwise in the troubleshooting procedures PROBLEM 1 THE UNIT HAS NO POWER MAIN POWER LED DOES NOT LIGHT UP 1 Check if the unit is switched ON 2 Check the fuse Replace with the same type of fuse if blown...

Page 5: ...the fuse holder 5 Temperature may reach a high of 480 C when turned on Do not use near inflammable flammable materials Do not touch heated parts can cause severe burns Do not touch metallic parts near...

Page 6: ...lement to ensure proper connections Pins 4 2 Pins 4 1 Pins 5 1 Pins 5 2 Warning Ensure none of the above mentioned conditions are present before plugging in the hand piece Failure to do so can damage...

Page 7: ...caused by cold solder double check solder points if the heating element has recently been replaced Heating element Sensor Heating element Test the resistances of the following configurations at the 5...

Page 8: ...intains the tinning on the tip and the tip will last much longer Many technicians mistakenly clean the tip before they put the iron into the holder Leave the solder on the tip to protect it SOLDER TIP...