OPERATING PROCEDURES 

D.  TYPE “2”  OPERATION  

    Before proceeding with this type of operation, attach the first external 
temperature probe (Marked “B”) to the underside of the PCB to be worked 
on. The second probe can be placed near areas of interest. Such as near 
the component to be worked on. 
    This type of operation utilizes the first external temperature sensor to 
control the heat. Type “2” operation uses the profile to slowly control the 
rise and fall of the temperature at board level. While the second external 
temperature probe can be attached for additional monitoring.  
 
1.  To enter type “2” mode. Select 2 at the initial screen then press the 

select button. The display would change to “run Prof”. This signifies 
we are now in the type “2” mode. 

2.  To adjust the time and temperature profile of each segment press the 

selection button. The top display will show which segment “SEG1  we 
are currently adjusting while the bottom display shows whether we are 
adjusting the time (suffix “t”) or temperature (suffix “C”). 

3.  Press the increase or decrease button to adjust the desired time and  

temperature. The set temperature is adjustable from 50 to 250 C and 
time  5 to 200 seconds.   

4.  To start preheating with the profile, repeatedly press the  selection 

button until the display shows the word “Run Prof” then press the 
increase button. A 3 second countdown will commence before 
automated reworking starts. 

5.  To see the running time, or current segment the system is processing 

or the temperature of the external temperature probes. repeatedly 
press the  selection button to switch between different views. Follow 
the suffix guide to determine  displayed temperature. 

6.  After the process is finish the display will show “End”,  press the 

increase button to save the profile and exit to profile adjustment 
mode. 

7.  To exit before the process is finished press the increase button while 

the profile is running. The system would exit and return to profile 
adjustment mode.  

 

3  

 

 

 

CARE and SAFETY PRECAUTIONS 

CAUTION: 

Improper usage can cause injury and physical damage. 

For your own safety, please observe the following precautions. 

● 

Temperature may reach as high as 500°C when turned ON. 

Do not touch the heating element inside the pre-heater. 

Do not expose skin to infra-red light for long periods.  

Prolonged exposure may damage the skin tissue. 

● 

Handle with care 

Never drop or sharply jolt the unit. 

Contains delicate parts such as IR tubes that may break if the 
unit is dropped. 

Do not spill any liquid to the system. 

● 

Do not tamper the electrical control unit or any wiring inside the 
device.  

● 

Disconnect plug from main power source if the device will not be 
used for a long period.  

Turn off power during breaks, if possible. 

● 

Allow ample time for the equipment to cool down before 
commencing maintenance.

  

● 

Use only genuine replacement parts. Turn-off power and let the unit 
cool down before replacing any component. 

  

Summary of Contents for Int883

Page 1: ...hows err2 internal temperature connector might have come loose or needs to be replaced If err messages shows err3 the first external temperature probe was not detected secure the external temperature on the underside of the board to be worked on PROBLEM 3 DISPLAY AND OTHER DEVICE OPERATION ISSUES SOLUTION Turn off power and back on OTHER PROBLEMS NOT MENTIONED Contact the vendor IR Preheating Syst...

Page 2: ... when it is switched on Rohs Correct Disposal of this product This marking indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return and coll...

Page 3: ... will commence before automated reworking starts 5 To see the running time or current segment the system is processing or the temperature of the external temperature probes repeatedly press the selection button to switch between different views Follow the suffix guide to determine displayed temperature 6 After the process is finish the display will show End press the increase button to save the pr...

Page 4: ...ot air or IR top heating systems 9 OPERATING PROCEDURES D TYPE 1 OPERATION Before proceeding with this type of operation attach the first external temperature probe to the underside of the PCB to be worked on The second probe can be placed near areas of interest This type of operation utilizes the first external temperature sensor Marked B to control the heat Using this type of operation allows us...

Page 5: ...perature of second external temperature probe followed by a suffix c 6 To simultaneously view the actual temperature read by the first and Second external temperature probe repeatedly press the selection button until the top display shows the actual temperature of first external temperature probe followed by a suffix b and the bottom display shows the actual temperature of second external temperat...

Page 6: ...ontrol panel guide B OPERATION TYPE MODE SELECTION 1 Follow initial procedures A INITIAL PROCEDURES 2 The display would show TYPE 0 which means Type 0 operation will be used To select between types 0 to 2 Press the increase or decrease buttons 3 4 of control panel guide 3 To confirm selection and enter into operation mode using the selected type Press the selection button 2 of control panel guide ...

Reviews: