background image

8  

!

 

OPERATING PROCEDURES 

2. 

Press  the  increase  or  decrease  button  to  adjust  the  set 
temperature  level.  The  set  temperature  is  adjustable  from 
50 to 400 C in this type of operation.   

3. 

To  view  the  actual  temperature  read  by  the  internal 
temperature  probe,  repeatedly  press  the    selection  button 
until  the  top  display  shows  the  word  “

Act3

”,  and  the 

bottom  display  shows  the  actual  temperature  of  internal 
temperature probe followed by a suffix “

d

”. 

4. 

To  view  the  actual  temperature  read  by  the  first  external 
temperature  probe,  repeatedly  press  the    selection  button 
until  the  top  display  shows  the  word  “

Act1

”,  and  the 

bottom  display  shows  the  actual  temperature  of  first 
external temperature probe followed by a suffix “

b

”. 

5. 

To view the actual temperature read by the Second external 
temperature  probe,  repeatedly  press  the    selection  button 
until  the  top  display  shows  the  word  “

Act2

”,  and  the 

bottom  display  shows  the  actual  temperature  of  second 
external temperature probe followed by a suffix “

c

”. 

6. 

To simultaneously view the actual temperature read by the 
first  and  Second  external  temperature  probe,  repeatedly 
press  the    selection  button  until  the top  display  shows  the 
actual  temperature  of  first  external  temperature  probe 
followed by a suffix “

b

”. and the bottom display shows the 

actual  temperature  of  second  external  temperature  probe 
followed by a suffix “

c

”. 

 

Note: External temperature probes are color coded. 
The first external temperature probe is  the red and blue pair. 
While the second external temperature probe is all white. 

5  

!

 

SPECIFICATIONS 

  Power Input: 

Available in 110V / 220V 

  Dimensions: 

450(l) x 260(w) x 80(h) mm 

  Power Consumption: 

850W (maximum) 

  Temperature Range: 

50°C - 400°C

(^maximum) 

  Heating Element: 

IR Heating 

  Pre-Heating Area: 

250mm  x 200mm 

 

PACKAGE INCLUSION 

^Depends on type of operation 
*Specifications subject to change without prior notice 

Instruction Manual 

Power Cord 

863 Main Station  

Temperature probe 

Summary of Contents for Int863

Page 1: ...still intact If err messages shows err2 internal temperature connector might have come loose or needs to be replaced If err messages shows err3 the first external temperature probe was not detected secure the external temperature on the underside of the board to be worked on PROBLEM 3 DISPLAY AND OTHER DEVICE OPERATION ISSUES SOLUTION Turn off power and back on OTHER PROBLEMS NOT MENTIONED Contact...

Page 2: ...3 degrees per second Therefore based on your set time the maximum temperature may not reach 250C Profile analysis SEG1 SEG2 SEG3 SEG4 SEG5 SEG6 050t 060t 080t 050t 040t 60t 100C 150C 180C 190C 195C 100C Segment one is set to 50 seconds to reach 100C Which means after 50seconds at the end of segment one the temperature should reach 100C Then Segment two is set to 60 seconds to reach 150C which mean...

Page 3: ...he profile repeatedly press the selection button until the display shows the word Run Prof then press the increase button A 3 second countdown will commence before automated reworking starts 5 To see the running time or current segment the system is processing or the temperature of the external temperature probes repeatedly press the selection button to switch between different views Follow the su...

Page 4: ...with either hot air or IR top heating systems 9 OPERATING PROCEDURES D TYPE 1 OPERATION Before proceeding with this type of operation attach the first external temperature probe to the underside of the PCB to be worked on The second probe can be placed near areas of interest This type of operation utilizes the first external temperature sensor to control the heat Using this type of operation allow...

Page 5: ...shows the word Act2 and the bottom display shows the actual temperature of second external temperature probe followed by a suffix c 6 To simultaneously view the actual temperature read by the first and Second external temperature probe repeatedly press the selection button until the top display shows the actual temperature of first external temperature probe followed by a suffix b and the bottom d...

Page 6: ...rn the unit ON Toggle the main power switch to ON position 7 on control panel guide B OPERATION TYPE MODE SELECTION 1 Follow initial procedures A INITIAL PROCEDURES 2 The display would show TYPE 0 which means Type 0 operation will be used To select between types 0 to 2 Press the increase or decrease buttons 3 4 of control panel guide 3 To confirm selection and enter into operation mode using the s...

Reviews: