Declaration of Conformity
International Standards Laboratory
Report Number: ISL-99135FB
(NVLAP Lab. Code: 200234-0)
-4-
2.2 Test Data:
Table 2.2\1
Power Line Conducted Emissions (Average)
Power Line Conducted Emissions
Conductor
Frequency
(MHz)
Peak Amplitude
(dBuV)
Limit
(dBuV)
Margin
(dB)
Hot
0.199
47.10
53.64
-6.54
Hot
0.302
36.00
50.18
-14.18
Hot
0.502
38.70
46.00
-7.30
Hot
0.602
34.40
46.00
-11.60
Hot
0.703
29.20
46.00
-16.80
Hot
0.816
26.70
46.00
-19.30
Hot
0.906
28.40
46.00
-17.60
Hot
1.380
26.10
46.00
-19.90
Hot
3.290
22.40
46.00
-23.60
Hot
5.230
22.90
50.00
-27.10
Hot
9.900
22.50
50.00
-27.50
Hot
15.440
19.70
50.00
-30.30
Hot
17.790
21.60
50.00
-28.40
Hot
20.400
17.90
50.00
-32.10
Hot
22.260
16.60
50.00
-33.40
Hot
26.720
15.30
50.00
-34.70
Neutral
0.199
46.70
53.64
-6.94
Neutral
0.301
34.70
50.23
-15.53
Neutral
0.404
29.00
47.77
-18.77
Neutral
0.504
33.10
46.00
-12.90
Neutral
0.604
36.50
46.00
-9.50
Neutral
0.729
25.70
46.00
-20.30
Neutral
0.804
29.40
46.00
-16.60
Neutral
0.905
35.00
46.00
-11.00
Neutral
1.320
34.40
46.00
-11.60
Neutral
3.320
29.50
46.00
-16.50
Neutral
10.160
27.20
50.00
-22.80
Neutral
13.930
27.30
50.00
-22.70
Neutral
15.960
28.30
50.00
-21.70
Neutral
18.170
27.10
50.00
-22.90
Neutral
20.660
26.30
50.00
-23.70
Neutral
22.660
24.60
50.00
-25.40
Neutral
26.870
21.80
50.00
-28.20
* NOTE:
Margin = Quasi-Peak Amplitude - Limit
A margin of -8dB means that the emission is 8dB below the limit ( in compliance)
Test Engineer: David Y.Y. Wu