background image

 

Aode Machinery Co., Ltd                                                                                                  Page 1 of 26 

奥德机械有限公司

 2012

 

 

 

PREFACE 

 

AWM

模具温度控制机操作说明书

AWM Instruction Manual of Mold Temperature Controller; 

1

、提供温度控制方面的领先技术,以优良的品质,适中的价位,完善的服务为客户创造价值

 

We provide advanced technology in temperature controlling and create values for customers 

with top quality, reasonable price and perfect service.

 

2

、本手册说明如何操作使用此模温机,它同时提供一些平常保养事项及可预见问题的故障处理。

 

This manual illustrates how to operate the mold temperature controller and provides ordinary   

maintenance items and solutions to predictable faults. 

3

、为了操作人员对本设备能最有效安全的使用,请详阅本手册。

 

In order to make the most effective and safe use of the equipment

  please read this manual   

carefully.

 

4

、如有不明之处,请致电

 

深圳工厂

0755-33232001/2/3/4

812

   

苏州工厂

0512-57115761/2/3

812

 

天津工厂

022-26899171/3/9

818

,有专员为您解答。

 

维修

24

小时热线:深圳

 +86-13923892924/ +86-13823573023 

                                 

苏州

  +86-13914978909 / +86-15850359345 

                                               

天津

 +86-13512948118/ +86-13516101512 

If any question, please contact with our technical supporter as below: 

  Shenzhen 

plant: 

0755-33232001-4 Ext: 812   

Suzhou plant:  0512-57115761-3 Ext: 812 

Tianjin plant

  022-26899171/3/9 Ext: 818 

24 Hours hotline: Shenzhen Plant: +86-13923892924/ +86-13823573023 

     

 

Suzhou 

Plant:   +86-13914978909 / +86-15850359345 

                                Tianjin Plant

  +86-13512948118/ +86-13516101512 

Summary of Contents for AWM-05

Page 1: ...Instruction Manual of AWM Mold Temperature Controller AWM 24 Hours Hotline AODE MACHINERY 86 13914978909 86 15850359345 SU ZHOU PLANT 86 13923892924 86 13823573023 SHEN ZHEN PLANT AODE MACHINERY 86 1...

Page 2: ...s 3 In order to make the most effective and safe use of the equipment please read this manual carefully 4 0755 33232001 2 3 4 812 0512 57115761 2 3 812 022 26899171 3 9 818 24 86 13923892924 86 138235...

Page 3: ...rts 8 Chapter Four Specifications 11 Chapter Five Main Functions 12 Chapter Six Installation and Precautions 16 Chapter Seven Operating Instructions 21 Chapter Eigth Abnormal Phenomena and Solutions 2...

Page 4: ...Do not touch the switch with wet object or hands Do not use the machine before fully aware of its performance Be careful not to touch or hit the switch or sensor Please keep enough space for operatio...

Page 5: ...table temperature cooling water pressure between 1 5 kg cm and 3kg cm and outlet of pressure should less than 0 5 kg cm Y Clean the Y type strainer to ensure cooling capacity of the machine This sing...

Page 6: ...re s need of repairing we must wait for water temperature falling below 30 degree 4 60 Before shut off the pump must wait until water temperature falls below 60 Otherwise The service life of the unit...

Page 7: ...h automatic air exhaust 4 Temperature display of outlet and returned water 5 Pipeline with explosion proof apparatus 6 Mold water return function option 7 WEST ABB MOELLER WEIDMULLER Controlling acces...

Page 8: ...Ltd Page 7 of 26 2012 Chapter Three Names of parts Electric Box Nameplate Temperature Controller Contro Panel Pressure Gauge Hot Water Outlet Hot Water Inlet Cooling Water Outlet Power Supply Wire Co...

Page 9: ...pe Circulation water pipe L W H Weight 1 2 1 95 900 420 900 AWM 20 24 24 2 150 2 0 26 KW HP L min kg c KW INCH INCH MM KG AWM 05A 6 0 5 16 2 0 7 1 2 3 8 2 620 325 580 50 AWM 05 6 0 5 25 2 5 7 1 2 3 8...

Page 10: ...Aode Machinery Co Ltd Page 9 of 26 2012 4 2 Pump performance curve...

Page 11: ...Aode Machinery Co Ltd Page 10 of 26 2012...

Page 12: ...his process repeats again and again The medium water is heated up by the heater G and its temperature is detected by temperature detector K When the temperature reaches the required point heater G wil...

Page 13: ...B 120 Intermediate pressure leather hose 120 about one year C 200 Teflon pipe 200 about one year 120 Notes Quick coupler is suitable when temperature is below 120 but oil pressure coupler must be use...

Page 14: ...ts 6 2 2 Pipeline connect method with Mold 1 Cooling water circulating system a Connect heat resistant water pipes according to the size of cooling water inlet b Connect the returning water pipe of co...

Page 15: ...Aode Machinery Co Ltd Page 14 of 26 2012 5...

Page 16: ...Aode Machinery Co Ltd Page 15 of 26 2012 3 Wire Connection of Power Supply AWM 10 AWM 10A MAIN POWER CIRCUIT DIAGRAM...

Page 17: ...m Use for jam clearing 4 Simple flow chart M C operation flow Note M C operating reference flow 5 Indicating lamp M C running status Note Let us know machine performance 6 Medium return temp Show mold...

Page 18: ...e Return water temperature in the show appeared that the number of working hours start to cool for the second unit Press the start off button the starting up cooling time the figure of the return wate...

Page 19: ...motor thermal relay and check if the three phase power supply is default phase When replace new molds please cooling first to increase the service life of heater 2 2 3 There are two ball valves in the...

Page 20: ...ture value 6 PV Display the practical temperature value 7 Indicator light of condition and signal 8 Indicator light of heating and cooling signal Note Just press and to set the temperature Do not pres...

Page 21: ...Aode Machinery Co Ltd Page 20 of 26 2012 Setting up of temperature controller AWM 120 Note the highest temp of AWM type unit is 120...

Page 22: ...Aode Machinery Co Ltd Page 21 of 26 2012...

Page 23: ...let 3 Cooling water or filling water port blocked 3 Clean up the filter 3 Pump overload alarming 1 System overload 1 05A 10A Check if the hot water inlet outlet valve is open and press the reset key 2...

Page 24: ...PC board 4 PC Replace the PC board 5 Fail to heating 1 Solenoid valve blocked or damaged 1 Clear up the sundries of water hole in solenoid valve or call us 2 Heater burnt out 2 Replace the heater or c...

Page 25: ...ing rules during maintenance 30 During operation the water is heated up to a high temperature Stop the machine before service and wait it to fall below 30 to perform repairing or maintenance Please no...

Page 26: ...Aode Machinery Co Ltd Page 25 of 26 2012 Chapter Ten Pipeline System Chart...

Page 27: ...Aode Machinery Co Ltd Page 26 of 26 2012 Chapter Eleven Circuit Diagram and List of Electronic Parts...

Page 28: ...Aode Machinery Co Ltd Page 27 of 26 2012...

Page 29: ...Aode Machinery Co Ltd Page 28 of 26 2012...

Page 30: ...Aode Machinery Co Ltd Page 29 of 26 2012...

Page 31: ...Aode Machinery Co Ltd Page 30 of 26 2012...

Page 32: ...Aode Machinery Co Ltd Page 31 of 26 2012...

Page 33: ...henzhen City China TEL 0755 33232001 33232002 33232003 FAX 0755 29623772 E mail aode gdaode com website http www gdaode com Suzhou Company ADD Qiang an Road Wulian Village Private operated Economic De...

Reviews: