Terminal layout

* The total length refers to 
   the total of the used cables. 

Eject check switch
(Lever type)

Included

-A027XB02*2P 2/5-

A027XB-02

2-P

A027XB-02

2-P

A027XB-02

2-P

Transmission line (Bitty line)

Connect transmission lines 

DP

 and 

DN

 correctly.

Installation of transmission lines

 

Keep route transmission lines away from high-voltage and power cables. 

 

Assign one transmission cable to one system of 

AB023

-

□□□

. If multiple systems are used, assign a cable to each system.

If multiple systems are combined by a multi-wire cable, a malfunction may occur.

AnyWire transmission line error

 

When the transmission line is not working properly, 

output is reset

.

Power supply to the AnyWire System

Install an 

AnyWire

 system-dedicated power supply to provide 24V DC power.

1

2

4

8

16

32

64

128

LINK

ADDRESS

ON

A027XB-02G2-P

ADDRESS No.

1

2

4

8

16

32

64

128

LINK

ADDRESS

ON

A027XB-02G2-P

ADDRESS No.

1

2

4

8

16

32

64

128

LINK

ADDRESS

ON

A027XB-02G2-P

ADDRESS No.

Eject indicator lamp

Master

30m or less

10m

or less

40-42 units

Pay attention to crimping direction of the link connector.

Improper connection results in malfunction or failure.

The hinge part side of the connector cover is the black line.

For details of link connector pressure welding work, refer to “How to pressure-weld link connector to flat cable” in our separate manual.

(Contact our Sales Department.)

At time of 

terminal treatment

At time of 

intermediate 

treatment

Connector cover

Connector cover

Terminator AT0

LED

Black (DN)

White (DP)

Transmission distance

within the maximum length 

of 100 m

24V DC stabilized 

power supply for 

general-purpose

24V
0V
DP
DN

: Green
: White
: Red
: Black

24V
0V
DP
DN

: Green
: White
: Red
: Black

24V
0V
DP
DN

: Green
: White
: Red
: Black

Wiring of POKA-YOKE Terminal

Manufacturer: Sumitomo 3M Limited
Applicable connector: Link connector

Cable used: 0.75mm

2

/4-wire flat cable

Applicable connector: FK4-075-100 (100m)

Cable used: 0.75mm

2

/4-wire flat cable

Applicable connector: FK4-075-100 (100m)

AB023-C1L

Input: 256 points

Output: 256 points

AB023-D1

Input: 256 points

Output: 256 points

FG

DG

SLD

DB

DA

CC-Link

Bit distribution I/O 

terminal

DeviceNet

Bit distribution I/O 

terminal

-V

+

V

CANLDrain

CANH

Connector layout

Type

Compatible Open Bus

[Connection Example]

Install an AnyWire 

dedicated power 

supply to supply to 

the entire system.

24V DC stabilized 

power supply set 

voltage 26.4V.

Select capacity 1.3 

times of required 

consumption 

current.

Transmission line consists of 

four wires including power 

supply by our flat cable 

(FK4-075-100).

Under this condition, number 

of units of A027XB-02

2-P 

connectable to 

AB023-

□□□

 is up to 128 

units per one system.

The terminator (AT0) is a composite element to 

stabilize the transmission wave form.

Connect it at a position at the furthest end from 

the master in the transmission line.

Note that it has own polarities.

(The LED lights up in a normal state.)

Improper connection may cause a malfunction 

or a failure.

In order to turn ON the eject 

check switch without fail, tilt 

the lever at least approximately 

30°or more.

The lever is allowed to be tilted 

in any direction.

When connecting 128 units, refer to 
the following configuration as an 
example of using power efficiency 
most efficiently.

Use the cable with a connector protruding from the back 

of the unit.

Connect the cable, being careful not to reverse the 

connection or cause a short circuit.

When swaging by the link connector, we recommend 

using a dedicated tool that can realize stable work 

quality.

    (L-TOOL-N: SUZUDEN CORPORATION)

When making the connection, make sure that the 

cable is not under tension.

In addition, do not fix the unit while the cable is 

under tension.

Trunk line side

If a shock of 0.49 G or greater is applied to the 
eject check switch, it may cause damage.
Do not force the lever, such as by "twisting it" 
or "pulling it downward." Doing so may damage 
the eject check switch.

CAUTION

CAUTION

CAUTION

CAUTION

CAUTION