(7-segment display)
Fiber side
Transmission side
ON/OFF threshold display (Green)
Light receiving level display (Red)
-L*F1011 8/11-
■
Setting for operation mode change
Set if there is a diagnosis mode.
Variable
0
Disabled (Simple mode)
1
Enabled (Normal mode)
Default: 0
- Address writer (ARW-04): Parameter 07
■
Light ON/Dark ON setting
Set Light ON/Dark ON.
Variable
Details
0
Transmission type dark (shielding) ON
1
2
Reflection type dark (w/o reflection) ON
3
Default: 0
- Address writer (ARW-04): Parameter 06
■
Light receiving level display setting
Set the display of the light receiving level.
Variable
0
1
Default: 0
- Address writer (ARW-04): Parameter 08
Transmission type light (transmission) ON
Reflection type light (w/ reflection) ON
■
Light emitting power setting
Set the light emitting level.
Variable
Details
0
High
1
2
Low
Default: 0
- Address writer (ARW-04): Parameter 09
Middle
AD value display (0 - 4095 Digit)
0 - 100% display
■
ON Delay setting
Set the ON delay time.
Default: 0
- Address writer (ARW-04): Parameter 10
Variable
0 - 999
100ms
Unit
Set the OFF delay time.
Default: 0
- Address writer (ARW-04): Parameter 11
Variable
0 - 999
100ms
Unit
Set the One Shot time.
Default: 0
- Address writer (ARW-04): Parameter 12
Variable
0 - 999
100ms
Unit
■
Address/Parameter automatic setting (base unit only)
Automatically set the address and parameter.
Variable
0
Automatic setting disabled
1
2
Automatic setting for parameter only
3
Default: 0
- Address writer (ARW-04): Parameter 17
Automatic setting for address only
Address/Parameter automatic setting
* Linked to base unit's parameters.
“3”
Extension
Extension
Extension
Base
Setting address
“0”
“2”
“1”
Allot
Example)
For parameter 17 value 1
■
7-segment display orientation switch setting (base unit only)
Variable
0
1
Default: 0
- Address writer (ARW-04): Parameter 18
Normal display
180° flipped display
0: Normal display
Transmission side
Fiber side
1: 180° flipped display
■
OFF Delay setting
■
One Shot setting
Details
Details
Details
Details
For "Parameter 8 variable 0: AD value display" - Displays
the threshold set in the scope of 0 - 4095.
For "Parameter 8 variable 1: 0 - 100% display" -
Displays the setting threshold from 0 - 100%, with the
minimum AD value from teaching as 0 and the maximum
as 100%.
For "Parameter 8 variable 0: AD value display" - Displays
the amount of light received converted as an AD value
set in the scope of 0 - 4095.
For "Parameter 8 variable 1: 0 - 100% displays" -
Displays the received light from 0 - 100%, with the
minimum AD value from teaching as 0 and the maximum
as 100%.
This functional automatically reflects in the extension unit the addresses and
parameters set in the base unit.
If this automatic setting mode is enabled (value 1, 2, or 3), addresses and
parameters set to the base unit are automatically alloted to the extension unit.
This function flips the 7-segment display by 180°.
This is convenient when, depending on the orientation of this product, the
numbers are difficult to read.