background image

AnyWireASLINK System Products Guide

Extension

ASLINKAMP 

[Fiber Amplifier (7-segment Display Type)]

L

-F1011

[Notes on Safety]

A WARNING indicates a potentially hazardous situation which, if not 
handled correctly, could result in death or serious injury.

A CAUTION indicates a potentially hazardous situation which, if not 
handled correctly, may result in personal injury or property damage.

[Function]

[Warranty]

[Type]

WARNING

CAUTION

Precautions that must be observed in order to use this system safely are 
indicated as shown below. You must observe these precautions.

 Warranty period

The warranty on the delivered Product shall continue to be effective for one (1) 
year after the delivery thereof to a location as designated by the original owner.

 Scope of warranty

Should a defect occur in any part of the Product during the foregoing warranty 
period when it is used normally in accordance with the specifications described 
in this User's Manual, the Company shall replace or repair the defect free of 
charge, except when it arises as a result of:
[1] Misuse or abuse of the Product by the owner; 
[2] Fault caused by cause other than the delivered Product;
[3] Unauthorized modification or repair of the Product by any party other than 

the Company;

[4] Any unusual force of nature, disaster, or other cause beyond the Company's 

control.

The term "warranty," as used herein, refers to the warranty applicable to the 
delivered product alone. The Company shall not be liable for any damages 
consequential or incidental to a malfunction of the delivered product.

 Repair at cost

After the expiration of the warranty period, any troubleshooting or repairs shall 
be done at the expense of the owner.
Even during the warranty term, any repairs and troubleshooting for defects 
arising from causes outside the scope of the warranty as specified above shall 
be done at the owner's expense.

LA-F1011

1CH (Base unit)
1CH (Extension unit)

Fiber amplifier
(7-segment display type)

LB-F1011

[Included items]

[Name of each part]

LA-F1011 (Base)
LB-F1011 (Extension)

Amplifier body...1
Amplifier body...1

Expansion connector

LED display

7-segment display

Protective cover

Base

LED display

7-segment display

Protective cover

Transmission line

LINK

IN

ALM

LINK

IN

ALM

ASLINKAMP four-wire (isolated)
General-purpose fiber head

Connection targets

Model

Functions

Sensitivity adjustment (Threshold)
Hysteresis
Light ON/Dark ON

Sensing level drop

One-shot

Light receiving level display switch
Light emitting power

Address/Parameter automatic setting
7-segment display orientation

Delay timer

-L*F1011  1/11-

Bit operation

Slave unit voltage drop

CAUTION

WARNING

 System Safety

This system is intended for general industrial applications. It does not 
have functions for supporting applications requiring higher levels of safety 
such as safety-related devices or accident prevention systems.

 Always turn off the system power before attempting to mount or replace.

 Prolonged continuous flow of a rated load current or higher or a transit 

current due to load short-circuit or similar problem, in the hybrid unit 
including the output unit and the output circuit may result in smoke 
generation or fire. An external safety device such as a fuse must be 
installed.

 System power supply

Use a stabilized 24V DC power supply. Use of a non-stabilized power 
supply may cause problems with the system.

 Separately route high-voltage and power cables

Although the AnyWireASLINK has a high noise margin, lay the 
transmission lines and I/O cables so as to keep them away from 
high-voltage and power cables.

 Connectors and terminals

 Pay careful attention to the length and installation of cable wiring to 

ensure that connectors and cables are neither stressed nor 
disconnected even if they are stressed.

 Make sure to prevent any metal objects from getting inside the 

connectors or the terminal blocks.

 Short-circuits caused by metal objects or mis-wiring are likely to 

damage the device.

 Do not impose any external loads on the units.

Doing so may cause a failure.

 Do not disconnect or reconnect between the transmission line and slave 

units when a transmission line is operating.
A malfunction may occur.

 Use the AnyWireASLINK within the range of the specifications and 

conditions shown below.

Summary of Contents for ASLINKAMP L-F1011 Series

Page 1: ...ion Amplifier body 1 Amplifier body 1 Expansion connector LED display 7 segment display Protective cover Base LED display 7 segment display Protective cover Transmission line L IN K IN A L M L IN K IN...

Page 2: ...th of the transmission line and the supply current Table 1 L F1011 2 11 Connection Example You can select use of either a two wire or four wire terminal for the AnyWireASLINK according to the load cur...

Page 3: ...5A 24V DC Filter of COSEL Co Ltd EAC 06 472 MAX 6A 24V DC Model Type Allowable power current Filter allowable power current Insert the ASLINK filter Type ANF 01 regardless of installation method and d...

Page 4: ...wer supply 24V 0V 24V 0V PE DP DN 24V 0V Four wire terminal DP DN 24V 0V Four wire terminal A B 24V 0V 24V 0V PE Filter notation in the drawing General purpose power supply filter Use if necessary Gen...

Page 5: ...l a separate block If only the LA F1011 and LB F1011 are connected a single system can support up to 128 units Hook movable latch A onto the DIN rail Push down on fixed latch D on the opposite side un...

Page 6: ...details L F1011 6 11 Connect the transmission line of the base unit to the transmission line from the master unit This terminal is a four wire isolated type that is used by connecting to DP DN 24V an...

Page 7: ...efault 50 Address writer ARW 04 Parameter 05 100ms Unit Alarm value monitor time setting Carry out setting with the work actually used 0 100 AD value 0 100 AD value 0 100 AD value 0 100 Setting scope...

Page 8: ...2 Automatic setting for parameter only 3 Default 0 Address writer ARW 04 Parameter 17 Automatic setting for address only Address Parameter automatic setting Linked to base unit s parameters 3 Extensi...

Page 9: ...ddress only Address Parameter automatic setting 0 1 Automatic setting for parameter only Linked to base unit s parameters 0 Address Parameter automatic setting Base unit only 1 2 3 09 0 High Middle 0...

Page 10: ...36 7 72 70 32 7 10 LINK IN ALM 200 10 LB F1011 Extension unit 7 36 7 72 72 32 10 14 25 LINK IN ALM 10 One point input IP40 Number of occupied points 24V 0V 25mA 1 9mA DP DN Consumption current Protec...

Page 11: ...1 Address Anywire Corporation Contact by mail Contact info_e anywire jp Contact by website http www anywire jp Headquarters 1 Babazusho Nagaokakyo shi Kyoto 617 8550 JAPAN Printed in Japan 2016 2017 U...

Reviews: