background image

-BL296*B08F****V50  4/22-

機    能

アドレス

×

×

Functions

×

×

×

接続対象例

仕  様

機  種

Lot No. 19ECBNB

NPN input: 8 points, NPN output: 8 points
NPN input: 4 points/output: 4 points
PNP input: 8 points, PNP output: 8 points
PNP input: 4 points/output: 4 points

Function

*

1  It depends on lot No. whether this function is available or not.

*

2  This terminal can be used in connection to the AnyWireASLINK unit for word transmission. Note that this terminal cannot handle word data by setting a word address.

*

3  To use these functions, a master unit that supports each function is required. For details, refer to the manual for the master unit together with this manual.

*

4  This terminal can be used in connection to the AnyWireASLINK unit for word transmission. Note that this terminal cannot handle word data by setting a word address.

Bit 

transmission

General-purpose 
sensors, switches 
General-purpose 
output devices

Single unit simplified replacement
Remote address change

Detection of 

sensor cable 

disconnection

Bit 

address 

setting

Slave unit voltage 

drop

Sensing level drop

I/O disconnection

I/O short-circuit

I/O power supply 

drop

Word 

address 

setting

Connection targets

Specifications

Model

Functions

Address

[Functions]

Function list

Detecting functions (Status details) 

Lot No. is indicated on the lot label.

Example:

How to check

Word transmission

*

4

S/W version

Function version

H/W version

Lot No.

This unit has undergone addition of functions and change of specifications according to version upgrading. 
Available functions and specifications of the unit vary depending on lot No.

[Function Compatibility by Lot No.]

Bottom of this unit

Available with S/W version “B” or later version
(If lot No. is indicated in 3 digits (year and 
month only), these functions are not available.)

ASLINKTERMINAL

4-wire (isolated) terminal 

with compact terminal block

Cable type

Compatible with 3-wire type 

sensor

Single unit 

simplified 

replacement

Remote 

address 

change

*

1

*

2

*

1

*

3

*

1

*

3

 Word

 

transmission

Summary of Contents for ASLINK BL296 B-08F V50 Series

Page 1: ...ncluding the output unit and the output circuit may result in smoking or firing An external safety device such as a fuse must be installed CAUTION WARNING Note on use A separate Address Writer is requ...

Page 2: ...Lot No About Word Transmission 3 Some products have no indication of function version Year Numbers Lower two digits of the Christian era Month Alphabet as per the table below 19E means May 2019 Single...

Page 3: ...lacement function see the lot No and the manual for the slave unit When a slave unit of a new function version is replaced with that of an old function version the single unit simplified replacement f...

Page 4: ...it simplified replacement Remote address change Detection of sensor cable disconnection Bit address setting Slave unit voltage drop Sensing level drop I O disconnection I O short circuit I O power sup...

Page 5: ...ching length or branch number has no limitation Include the length of the cable provided with the terminal in the total line length Connect the terminator with polarity to the DP DN terminal farthest...

Page 6: ...ing in parallel This will improve noise resistance suppress the adverse effects of crosstalk caused by transmitted signals and stabilize signals The above filters must be inserted regardless of whethe...

Page 7: ...Use it if necessary 2 wire terminal 4 wire terminal 4 wire terminal AnyWireASLINK master If the total length of the section where all the DP DN 24V and 0V lines run in parallel is more than 50m 24V DC...

Page 8: ...andard terminal block Cover mounting hole Mounting hole Bottom Lot label Bottom Lot label Cover mounting hole Mounting hole I O indicators Infrared port Spring terminal block I O indicators Infrared p...

Page 9: ...Power supply for terminal and connected load drive The 24V terminal of the transmission line connection cable is internally connected to the 24V pin of the terminal block The 0V terminal of the trans...

Page 10: ...minal and connected load drive The 24V terminal of the transmission line connection cable is internally connected to the 24V pin of the terminal block The 0V terminal of the transmission line connecti...

Page 11: ...and connected load drive The 24V terminal of the transmission line connection cable is internally connected to the 24V pin of the terminal block The 0V terminal of the transmission line connection ca...

Page 12: ...s setting An address number is set as a beginning number from which part of the transmission frame is occupied to the terminal Set the address number within the range of bit address 0 to 254 For the i...

Page 13: ...B 08F V50 Monitor Display If an error is indicated identify a cause of the error by checking lit flashing status with the table on the left and eliminate the cause of the error Once the cause of the...

Page 14: ...will be in the range from 21 6 to 27 6V Recommended voltage is 26 4V Check the total length Review the total length and wire diameter of transmission line so that the load will not exceed the current...

Page 15: ...rrent 30V DC 100mA Internal circuit To connect loads e g I O ports that are controlled with a power supply other than the one used for the AnyWireASLINK system always use a 4 wire isolated terminal Ot...

Page 16: ...nnect loads e g I O ports that are controlled with a power supply other than the one used for the AnyWireASLINK system always use a 4 wire isolated terminal Otherwise malfunction may be caused E g Use...

Page 17: ...nts 1024 words max Input 512 words Output 512 words Up to 128 units Detection of transmission line disconnection transmission line short circuit transmission power supply drop and duplicated unregiste...

Page 18: ...4 6 8 10 12 16 14 2 3 5 BL296 B08F V50 18 22 24V 0V 0 2 1 3 24V 0V 24V 0V 24V 0V 4 6 5 7 4 6 1 4 7 62 6 Outside Dimensions Unit mm M3 6 42mm pitch compatible with crimp terminal of 6mm in width When...

Page 19: ...4V 0V 24V 24V 0V 2 3 5 BL296 B08F V50 19 22 0V 24V 0V 0V 0V 24V 24V 24V 24V 24V 24V 24V 0V 0V 0V 0V 0 1 2 3 4 5 6 7 0 1 0V 2 3 0V 4 5 0V 6 7 4 6 1 4 Unit mm Black DN Red DP White 0V Green 24V UL style...

Page 20: ...0V 24V 0V 0V 0V 24V 24V 24V 24V 24V 24V 24V 0V 0V 0V 0V 0 1 2 3 4 5 6 7 0V 0 1 0V 2 3 0V 4 5 0V 6 7 24V 0V 24V24V0V 24V24V0V 24V 0V 24V 24V 4 6 1 4 Unit mm Black DN Red DP White 0V Green 24V UL style...

Page 21: ...24V 24V 24V 24V 24V 24V 24V 0V 0V 0V 0V 0 1 2 3 4 5 6 7 39 4 28 6 81 28 9 15 15 7 7 74 5 500 17 7 5 40 8 7 5 3 6 39 4 95 40 8 21 05 2 3 5 M ounting screw hole Unit mm DIN rail mounting For DIN rail mo...

Page 22: ...inted in Japan 2015 2016 2017 2018 2019 UMA 11306AK EN Anywire Corporation Headquarters 1 Babazusho Nagaokakyo shi Kyoto 617 8550 JAPAN Contact by mail Contact info_e anywire jp Contact by website htt...

Reviews: