background image

I/O 0

I/O 1

LINK

ALM

I/O 2

I/O 3

I/O 4

I/O 5

I/O 6

I/O 7

1
3

5

7

9

11

13

15

2

4

6

8

10

12

16

14

-BL296*B08F****V50  13/22-

b3

b4

b5

b7

b6

b2

b1

b0

b11

b12

b13

b15

b14

b10

b9

b8

BL296XB-08F

□□□□

-V50, BL296XB-08FS

□□□□

-V50

OUT0

n

IN0

OUT1

n+1

IN1

OUT2

n+2

IN2

OUT3

n+3

IN3

BL296SB-08F

□□□□

-V50, BL296SB-08FS

□□□□

-V50

BL296PB-08F

□□□□

-V50, BL296PB-08FS

□□□□

-V50

n+1

OUT1

n

OUT0

n+3

OUT3

n+2

OUT2

n+5

OUT5

n+4

OUT4

n+7

OUT7

n+6

OUT6

n+1

IN1

n

IN0

n+3

IN3

n+2

IN2

n+5

IN5

n+4

IN4

n+7

IN7

n+6

IN6

Address 

offset

Bit input 

Address 

offset

Address 

offset

Bit output 

Bit input 

Bit output 

[Data Configuration]

*

n = Bit address number assigned to this unit

*

1 This can be used on the master unit having the status detail area. For details, refer to the manual for the master unit.

Status
details

Status detail area of the master unit

b0: Slave unit voltage drop (DP-DN-side voltage drop)
b5: I/O power supply drop (24V-0V-side voltage drop)
 

Status details

The contents of an alarm detected with this unit can be checked with the “status detail area

*

1

” 

on the master unit.
A bit corresponding to the status detail area turns ON depending on the contents of the alarm.

This figure shows an example 
of BL296

B-08F

-V50.

[Monitor Display]

If an error is indicated, identify a cause of the error by 
checking lit/flashing status with the table on the left, and 
eliminate the cause of the error. 
Once the cause of the error is eliminated, the error 
indication will be automatically reset.

LED name

*

2 This indication appears when the use of the single unit simplified replacement function fails.

(This operation occurs on the S/W version “B” or later version.)

*

3 If ID duplication is detected when the master unit executes automatic address 

recognition, this indication appears.

*

4 For S/W version “B” or later version: This indication appears when transmission signal 

and power supply are normally connected, and the unit is set to the factory-set address. 

 

For S/W version “A” or 3-digit lot No.: This condition is detected when the master unit 

executes automatic address recognition.

LINK

(Green)

ALM

(Red)

Flashing

Lit

Unlit 

Flashing

Lit

Lit

Unlit 

Unlit 

Display status

Alternate flashing

Model mismatching error

*

2

Description

I/O power supply drop

No ALM available

Transmission signal received

Slave unit voltage drop

Model mismatching error

*

2

Transmission signal error
Model mismatching error

*

2

ID duplicated

*

3

 or ID unregistered

*

4

No transmission signal (disconnection and 

reverse connection of DP and DN lines included)

I/O

(Orange)

LINK

ALM

LINK

ALM

LINK

ALM

ON
OFF

LINK

ALM

Summary of Contents for ASLINK BL296 B-08F V50 Series

Page 1: ...ncluding the output unit and the output circuit may result in smoking or firing An external safety device such as a fuse must be installed CAUTION WARNING Note on use A separate Address Writer is requ...

Page 2: ...Lot No About Word Transmission 3 Some products have no indication of function version Year Numbers Lower two digits of the Christian era Month Alphabet as per the table below 19E means May 2019 Single...

Page 3: ...lacement function see the lot No and the manual for the slave unit When a slave unit of a new function version is replaced with that of an old function version the single unit simplified replacement f...

Page 4: ...it simplified replacement Remote address change Detection of sensor cable disconnection Bit address setting Slave unit voltage drop Sensing level drop I O disconnection I O short circuit I O power sup...

Page 5: ...ching length or branch number has no limitation Include the length of the cable provided with the terminal in the total line length Connect the terminator with polarity to the DP DN terminal farthest...

Page 6: ...ing in parallel This will improve noise resistance suppress the adverse effects of crosstalk caused by transmitted signals and stabilize signals The above filters must be inserted regardless of whethe...

Page 7: ...Use it if necessary 2 wire terminal 4 wire terminal 4 wire terminal AnyWireASLINK master If the total length of the section where all the DP DN 24V and 0V lines run in parallel is more than 50m 24V DC...

Page 8: ...andard terminal block Cover mounting hole Mounting hole Bottom Lot label Bottom Lot label Cover mounting hole Mounting hole I O indicators Infrared port Spring terminal block I O indicators Infrared p...

Page 9: ...Power supply for terminal and connected load drive The 24V terminal of the transmission line connection cable is internally connected to the 24V pin of the terminal block The 0V terminal of the trans...

Page 10: ...minal and connected load drive The 24V terminal of the transmission line connection cable is internally connected to the 24V pin of the terminal block The 0V terminal of the transmission line connecti...

Page 11: ...and connected load drive The 24V terminal of the transmission line connection cable is internally connected to the 24V pin of the terminal block The 0V terminal of the transmission line connection ca...

Page 12: ...s setting An address number is set as a beginning number from which part of the transmission frame is occupied to the terminal Set the address number within the range of bit address 0 to 254 For the i...

Page 13: ...B 08F V50 Monitor Display If an error is indicated identify a cause of the error by checking lit flashing status with the table on the left and eliminate the cause of the error Once the cause of the...

Page 14: ...will be in the range from 21 6 to 27 6V Recommended voltage is 26 4V Check the total length Review the total length and wire diameter of transmission line so that the load will not exceed the current...

Page 15: ...rrent 30V DC 100mA Internal circuit To connect loads e g I O ports that are controlled with a power supply other than the one used for the AnyWireASLINK system always use a 4 wire isolated terminal Ot...

Page 16: ...nnect loads e g I O ports that are controlled with a power supply other than the one used for the AnyWireASLINK system always use a 4 wire isolated terminal Otherwise malfunction may be caused E g Use...

Page 17: ...nts 1024 words max Input 512 words Output 512 words Up to 128 units Detection of transmission line disconnection transmission line short circuit transmission power supply drop and duplicated unregiste...

Page 18: ...4 6 8 10 12 16 14 2 3 5 BL296 B08F V50 18 22 24V 0V 0 2 1 3 24V 0V 24V 0V 24V 0V 4 6 5 7 4 6 1 4 7 62 6 Outside Dimensions Unit mm M3 6 42mm pitch compatible with crimp terminal of 6mm in width When...

Page 19: ...4V 0V 24V 24V 0V 2 3 5 BL296 B08F V50 19 22 0V 24V 0V 0V 0V 24V 24V 24V 24V 24V 24V 24V 0V 0V 0V 0V 0 1 2 3 4 5 6 7 0 1 0V 2 3 0V 4 5 0V 6 7 4 6 1 4 Unit mm Black DN Red DP White 0V Green 24V UL style...

Page 20: ...0V 24V 0V 0V 0V 24V 24V 24V 24V 24V 24V 24V 0V 0V 0V 0V 0 1 2 3 4 5 6 7 0V 0 1 0V 2 3 0V 4 5 0V 6 7 24V 0V 24V24V0V 24V24V0V 24V 0V 24V 24V 4 6 1 4 Unit mm Black DN Red DP White 0V Green 24V UL style...

Page 21: ...24V 24V 24V 24V 24V 24V 24V 0V 0V 0V 0V 0 1 2 3 4 5 6 7 39 4 28 6 81 28 9 15 15 7 7 74 5 500 17 7 5 40 8 7 5 3 6 39 4 95 40 8 21 05 2 3 5 M ounting screw hole Unit mm DIN rail mounting For DIN rail mo...

Page 22: ...inted in Japan 2015 2016 2017 2018 2019 UMA 11306AK EN Anywire Corporation Headquarters 1 Babazusho Nagaokakyo shi Kyoto 617 8550 JAPAN Contact by mail Contact info_e anywire jp Contact by website htt...

Reviews: