Back Panel 

 

 

 

RF_IN 

 

Connector: 

 

 

 

 

Impedance: 

 

 

 

50 Ω 

 

Rated Power:    

 

 

-6 dBm ± 1 dB 

 

Note: If input power from RF_IN is lower than rated input value, the output power will be lower 

than rated output power accordingly. This is because the PA has a fixed gain of 50 dB ± 1 dB. If 

the input level from RF_IN is higher than the rated value, it will result in RF output distortion 

and performance deterioration. If the input level is more than 1 dB higher than the rated value or 

the output power is higher than 25 W, it may trigger the current-limiting function of the internal 

power supply. The PA will enter the auto-protection mode, and there will be no RF output. 

 

 

RF_OUT 

 

Connector:     

 

 

 

Impedance: 

 

 

 

50 Ω 

 

Rated Power:    

 

 

25 W (+43.98 dBm) 

 

Note: RF_OUT must be connected with a load, otherwise the PA will enter the auto-protection 

mode and there will be in no RF output. Please note that the PA is designed to withstand any load 

conditions, including no load at all, without damaging the PA. However it is stongly suggested to 

have a load connected with proper impedance. 

 

 

RF MON (loop out of RF_OUT) 

 

Connector: 

 

 

 

BNC female   

 

Impedance: 

 

 

 

50 Ω 

 

Rated Power:    

 

 

+1 dBm ± 3 dB   

 

Note: It is OK to leave this port open without load. 

 

 

Summary of Contents for PA-25W

Page 1: ...ANYWAVE PA 25W User Manual Version 1 4 December 15 2014...

Page 2: ...for its use The manufacturer makes no representations or warranties either expressed or implied by or with respect to anything in this manual and shall not be liable for any implied warranties of fit...

Page 3: ...quired from Anywave for all equipment returns Please direct all return inquiries to the Anywave Service Department at support_us anywavecom com providing the Sales Order number and Serial Number s of...

Page 4: ...s a general guide for trained and qualified personnel well aware of the dangers inherent in handling potentially hazardous electrical transmission equipment The installation operation maintenance and...

Page 5: ...PA 25W User Manual ACT 25PA USR DOC V1 4 12 15 2014 Page 5 of 9 Contents 1 Product Appearance 6 1 1 Front Panel 6 1 2 Back Panel 7 2 Specifications 8...

Page 6: ...V1 4 12 15 2014 Page 6 of 9 1 Product Appearance 1 1 Front Panel RF Button Press the RF button to turn the RF signal ON inside blue light will light up Press the RF button again to turn the RF signal...

Page 7: ...ue or the output power is higher than 25 W it may trigger the current limiting function of the internal power supply The PA will enter the auto protection mode and there will be no RF output RF_OUT Co...

Page 8: ...WR 1 5 Shoulder Level 30 dBc before pre correction 25 W Note 1 The electrical interface characteristics are measured at rated power Values may change 2 Operating in abnormal conditions may result in d...

Page 9: ...A USR DOC V1 4 12 15 2014 Page 9 of 9 Anywave Communication Technologies Inc 300 Knightsbridge Parkway Suite 150 Lincolnshire IL 60069 Tel 847 415 2258 Fax 847 415 2112 Email sales_us anywavecom com h...