Initial Turn On   

Please locate and have handy for reference a copy of your 

25W TX Factory Test 

Report

  as  well  as  the 

25W  TX  Quick  Start  Guide

,  and 

25W  PA  and  Exciter 

User Manuals.

 

 

1.

 

With all equipment turned OFF, please make the cable connections according 
to  the  System  Interconnect  Diagram  of  section  4.  Make  sure  the  BPF  or  PA 
output  is  properly  connected  to  your  Antenna  feed  or  a  suitable  station  load 
before proceeding further. 

2.

 

Turn ON the Exciter via its rear panel AC switch. 

3.

 

Check  Exciter  settings.  Check  the  operating  Frequency  of  the  Exciter  by 
navigating to the Exciter FREQ submenu (simultaneously press Left and Right 
buttons) 

 
 
 
 
 
 
 
 

Check the Exciter drive level is set to -25dBm by navigating to the Exciter 
RF submenu (from above, press ESC button then enter the RF submenu). 

 
 
 
 
 
 
 

(Please refer to  your Exciter User Manual for help with  detailed operation of 
the Exciter).   
 

4.

 

Turn the 25W PA ON via the PA rear panel breaker, then press the front panel 
PA RF On/Off button to turn ON the PA - which should turn BLUE when ON. 
 

5.

 

The  built-in  Exciter  %FWD  power  meter  has  already  been  calibrated  at  the 
factory to indicate 100% for 30W of TX system forward power measured after 
the BPF.   

 
 

Summary of Contents for ATSC 25W

Page 1: ...ANYWAVE ATSC 25W DTV Transmitter Quick Start Guide Version 1 2 September 29 2014...

Page 2: ...sumed for its use The manufacturer makes no representations or warranties either expressed or implied by or with respect to anything in this manual and shall not be liable for any implied warranties o...

Page 3: ...re required from Anywave for all equipment returns Please direct all return inquiries to the Anywave Service Department at support_us anywavecom com providing the Sales Order number and Serial Number...

Page 4: ...ded as a general guide for trained and qualified personnel well aware of the dangers inherent in handling potentially hazardous electrical transmission equipment The installation operation maintenance...

Page 5: ...ATSC 25W TX Quick Start Guide ACT 25 QSG DOC V1 2 09 29 2014 Page 5 of 13 Contents 1 Introduction 6 2 Organization of Manual 6 3 TX System Overview 7 4 TX System Interconnect 8 5 Initial Turn On 9...

Page 6: ...personnel are required to install maintain and service this transmission equipment 2 Organization of Manual This Manual is broken up into several sections Section 3 TX system Overview Provides a gene...

Page 7: ...d of full power operating parameters and performance The TX then goes through a final 24 hour burn in period and check out before being shut done and packed up for shipment In your shipment you should...

Page 8: ...r 25W PA and a BPF optional with two additional single port couplers for Exciter feedback samples optional The diagram below shows the overall system interconnect between the system components To PC f...

Page 9: ...iter via its rear panel AC switch 3 Check Exciter settings Check the operating Frequency of the Exciter by navigating to the Exciter FREQ submenu simultaneously press Left and Right buttons Check the...

Page 10: ...power by using the UP button on the Exciter while monitoring the Fwd system power meter on the Exciter screen as shown below 7 Continue to slowly raise the FWD power until you reach 100 equivalent to...

Page 11: ...ients while RF IN B Before BPF is used to compute the Non Linear correction coefficients 10 Optional Step Navigate to the Exciter DPD submenu in the Advanced User menu simultaneously press Left and Ri...

Page 12: ...r Remote TX Monitoring and Control you may network to the Exciter REMOTE RJ 45 rear panel connection at 192 168 1 143 you can change the exciter ipaddress by navigating to the CONFIG submenu simultane...

Page 13: ...CT 25 QSG DOC V1 2 09 29 2014 Page 13 of 13 Anywave Communication Technologies Inc 300 Knightsbridge Parkway Suite 150 Lincolnshire IL 60069 Tel 847 415 2258 Fax 847 415 2112 Email sales_us anywavecom...

Reviews: