4
|
ANYLOAD OCSM Series Light Duty Crane Scale User’s Guide
3.
Specifications
Accuracy Class
Chinese GB/T 11883‐2002 Class III
Equivalent to OIML R76
Tare Range
100% F.S.
Zero Range
4% F.S.
Stable Time
≤10sec
Overload
100% F.S. + 9e
Safety Load
125% F.S.
Ultimate Load
400% F.S.
Battery
6V/5Ah lead acid battery.
Charger
AC220V or 110V input, DC9V/1500mA output
Op. Temp.
‐10
℃
~ +40
℃
Op. Humidity
20
℃
≤90%
Display
30mm (1.2inch) LED or 35mm(1.38inch) LCD
4.
Capacities
model
max. cap.
min. cap.
resolution
division
OCSM‐200lb
200lb
2lb
0.1lb
2,000
OCSM‐400lb
400lb
4lb
0.2lb
2,000
OCSM‐600lb
600lb
4lb
0.2lb
3,000
OCSM‐1000lb 1000lb
10lb
0.5lb
2,500
OCSM‐2000lb 2000lb
20lb
1lb
2,000
5.
Display & Keys
Scale & Remote Controller keys
key
name
function
On/Off
press for 1sec, power-on scale.
press for 1sec, power-off scale.
exit without saving
Zero
zero scale
with
, unit switch
increase digit
Tare
tare in/out
with
, tare set
right scroll digit