Anyload OCSM Series User Manual Download Page 5

 
 

ANYLOAD OCSM Series Light Duty Crane Scale User’s Guide

 

 

 

 

3.

 

Specifications 

 

Accuracy Class 

Chinese GB/T 11883‐2002 Class III 
Equivalent to OIML R76 

Tare Range 

100% F.S. 

Zero Range 

4% F.S. 

Stable Time 

≤10sec 

Overload 

100% F.S. + 9e 

Safety Load  

125% F.S. 

Ultimate Load  

400% F.S. 

Battery  

6V/5Ah lead acid battery. 

Charger  

AC220V or 110V input, DC9V/1500mA output 

Op. Temp.  

‐10

 ~ +40

 

Op. Humidity  

20

 ≤90% 

Display  

30mm (1.2inch) LED or 35mm(1.38inch) LCD 

 

4.

 

Capacities 

 

model 

max. cap.  

min. cap.  

resolution  
 

division 

OCSM‐200lb 

200lb 

2lb 

0.1lb 

2,000 

OCSM‐400lb 

400lb 

4lb 

0.2lb 

2,000 

OCSM‐600lb 

600lb 

4lb 

0.2lb 

3,000 

OCSM‐1000lb  1000lb 

10lb 

0.5lb 

2,500 

OCSM‐2000lb  2000lb 

20lb 

1lb 

2,000 

 

5.

 

Display & Keys 

 
Scale & Remote Controller keys 
 

key 

name 

function 

 

 

On/Off

 

press for 1sec, power-on scale.

 

press for 1sec, power-off scale.

 

exit without saving

 

 

 

Zero 

zero scale

 

with 

, unit switch

 

increase digit

 

 

 

Tare 

tare in/out

 

with 

, tare set

 

right scroll digit

 

Summary of Contents for OCSM Series

Page 1: ...OCSM Series Light Duty Crane Scale User s Guide...

Page 2: ......

Page 3: ...e Remote Controller keys 5 Indicators 5 Messages 5 6 Operations 6 On Off 6 Zero 6 Tare In Tare Out 6 Lock Unlock 7 Accumulate 7 View 7 Delete 8 Clear 8 Unit Switch 8 Tare Set 8 Resolution Switch 9 Bat...

Page 4: ...m Do NOT put the scale on the ground directly o Do NOT attempt to repair the scale by yourself Contact your local dealer or to the Technical Support 2 Features This scale is a combination of sound and...

Page 5: ...Temp 10 40 Op Humidity 20 90 Display 30mm 1 2inch LED or 35mm 1 38inch LCD 4 Capacities model max cap min cap resolution division OCSM 200lb 200lb 2lb 0 1lb 2 000 OCSM 400lb 400lb 4lb 0 2lb 2 000 OCSM...

Page 6: ...eft scroll digital View view accumulated weight with view battery level F1 NC Indicators indicator name note Stable lit when weight is stable Zero lit when weight is at zero Tare lit when weight is ta...

Page 7: ...off power Zero o Press or will zero the scale Indicator lights on o Scale must not be locked otherwise displays o Scale must be stable otherwise displays o Scale must not be tared otherwise displays...

Page 8: ...se displays o Press unlock scale Indicator lights off Accumulate o Press will accumulate the current weight will display indicating weight is accumulated Scale uses displayed weight so gross or net we...

Page 9: ...o kg displays indicator lights on some models do not have kg label or annunciator When unit switches to lb displays indicator lights on When unit switches to USR displays indicator and lights off o Un...

Page 10: ...r example if a 3000 1kg scale is switched to 3000 0 5kg it will overload at 3004 5kg 3000 9 0 5 while by default it overloads at 3009kg 3000 9 1 o Default resolution will be restored next time when sc...

Page 11: ...people s carelessness not to power off scale when it s not working Auto Off starts countdown timer when there s no action or load is stable Any key pressing or motion in load restarts countdown timer...

Page 12: ...on intelligently settles weight reading when scale is in motion The weaker Anti Motion is the faster weight reading displays but the longer it takes to be stable Anti Motion can be set to 0 off 1 weak...

Page 13: ...harge battery no action taken after key pressed scale is disturbed re plug power cable defective key contact representative weight reading not stable load in motion keep load stable weak Anti Motion c...

Page 14: ...13 ANYLOAD OCSM Series Light Duty Crane Scale User s Guide 10 Notes...

Page 15: ......

Page 16: ...ANYLOAD Weigh Measure Inc Website www anyload com Email info anyload com Fax 1 866 612 9088 North America Toll Free 1 855 ANYLOAD 269 5623...