![Anyload OCSL User Manual Download Page 11](http://html1.mh-extra.com/html/anyload/ocsl/ocsl_user-manual_2948887011.webp)
10
|
ANYLOAD OCSL Mini Type Crane Scale User’s Guide
5.
Calibration
Options
Display
Operations
Notes
Enter
Calibration
Mode
Hold and press [HOLD] and
[TARE] simultaneously, keep
pressing until SETUP
displays.
Enter Setup Mode
(At this stage set the unit of
measurement you are going to
calibrate, hold & press
the[HOLD/UNIT] to switch unit)
SETUP
Press [ON/OFF], [HOLD] and
[TARE] simultaneously, keep
pressing until SCALE
displays.
Enter Calibration
Mode
SCALE
Press [TARE].
Full Scale
_XXXX
Press [HOLD] to change
Full Scale and press [TARE]
to save setting.
For example, if you set
the unit at kg and setting
the parameter here to
600 then the full scale
should be 600kg else if it
was set to lb then the full
scale shall be equivalent
to 600lb.
Resolution
E X
Press [HOLD] to change
Resolution and press
[TARE] to save setting.
1/2/5
Decimal
Point
Pt X
Press [HOLD] to change
Decimal Point and press
[TARE] to save setting.
0: XXXXX
1: XXXX.X
2: XXX.XX
3: XX.XXX
Zero
Calibration
LoAd0
Press [TARE] to start zero
calibration.
Set the scale to no load
status and must be at stable
state.
-----
Load1
Calibration
_XXXX
Press [HOLD] to change 1st
Calibration Weight value.
Load the actual weight then
press [TARE] to start span
calibration.
If using test weight
equivalent to full scale
(FULL), the calibration shall
be finished at this stage.
-----
Load2
Calibration
_FULL
Load the 2
nd
test weight
then press [TARE] to finish
the calibration.
If 2
nd
test weight is not
needed, you can skip this
stage by pressing the
[ON/OFF] to finish and exit
the Calibration.
-----
_End_