Anyload OCSL User Manual Download Page 10

 
 

ANYLOAD OCSL Mini Type Crane Scale User’s Guide

 

 

 

 

o

 

When  Backlight  is  set  to  on,  the  scale’s  backlight  will  never  turn  off 
even if it is stable and no activities on it.

 

 

o

 

Press              to exit the Settings mode 

 

4.

 

Troubleshooting 

 

Symptoms 

Possible Causes 

Solutions 

blank display when 
On/Off is pressed 

discharged battery 

replace battery 

defective battery 
defective ON/OFF key 

press ON/OFF key 
for longer period 

no action 
taken after 
TARE or 
HOLD is 
pressed 

defective TARE or HOLD 
key 

clean TARE or HOLD 
key 

unstable readings 

scale in motion 

stabilize  the  load  and 
scale 

scale is damped 

dry the scale 

dust on PCB board 

clean PCB board 

reading is not in zero 
without load 

unstable system power 

longer warm‐up time 

load‐cell was 
stressed too much 
or too long 

hang  the  scale 
in storage 

large  error  in  weight 
reading 

scale is not zeroed 
before loading 

keep the scale 
unloaded and reboot 

re‐calibration needed 

re‐calibrate the scale 

wrong unit 

switch to correct unit 

 
 
 
 
 
 
 

Summary of Contents for OCSL

Page 1: ...OCSL Mini Type Crane Scale User s Guide...

Page 2: ...1 ANYLOAD OCSL Mini Type Crane Scale User s Guide...

Page 3: ...F CONTENTS 1 Introduction 3 2 Specifications 3 Features 3 Specifications 4 Capacities Resolution 4 Schematic Diagram 5 Dimensions 5 3 Operation Guide 6 Power On 6 Power Off 6 Tare 6 Hold 7 Unit Switch...

Page 4: ...ting the scale this may damage the load cell o Do NOT use scale under thunder or rain o Do NOT attempt to repair the scale by yourself Contact your local dealer or to the Technical Support 2 Specifica...

Page 5: ...activities within 3 min Overload 100 F S 9e Max Safety Load 120 F S Ultimate Load 300 F S Battery Life 150 hours Temp Op 10 40 Humidity Op 90 at 20 Display 0 7 inch 17 78mm numerical Net Weight 620g...

Page 6: ...5 ANYLOAD OCSL Mini Type Crane Scale User s Guide SCHEMATIC DIAGRAM DIMENSIONS...

Page 7: ...Display will show power off message TARE Press to store the weight as tare o TARE will appear and weight reading will turn to zero o If weight is greater than 100 F S or lesser than 0 taring is not a...

Page 8: ...hide and weight reading will resume UNIT SWITCH Press for 1 second to switch measuring unit between kg lb and N o If scale is in tare or in hold unit switching is not allowed ZERO Press for 1 second...

Page 9: ...bled 2 2 F S 4 4 F S 10 10 F S 20 20 F S 50 50 F S Press to enter Manual Zero options and press to select Manual Zero option o Manual Zero can also be set to 0 disabled 2 2 F S 4 4 F S 10 10 F S 20 20...

Page 10: ...FF key for longer period no action taken after TARE or HOLD is pressed defective TARE or HOLD key clean TARE or HOLD key unstable readings scale in motion stabilize the load and scale scale is damped...

Page 11: ...if it was set to lb then the full scale shall be equivalent to 600lb Resolution E X Press HOLD to change Resolution and press TARE to save setting 1 2 5 Decimal Point Pt X Press HOLD to change Decima...

Page 12: ...ANYLOAD Weigh Measure Inc Website www anyload com Email info anyload com Fax 1 866 612 9088 North America Toll Free 1 855 ANYLOAD 269 5623...

Reviews: