![Anyload OCSL User Manual Download Page 10](http://html1.mh-extra.com/html/anyload/ocsl/ocsl_user-manual_2948887010.webp)
9
|
ANYLOAD OCSL Mini Type Crane Scale User’s Guide
o
When Backlight is set to on, the scale’s backlight will never turn off
even if it is stable and no activities on it.
o
Press to exit the Settings mode
4.
Troubleshooting
Symptoms
Possible Causes
Solutions
blank display when
On/Off is pressed
discharged battery
replace battery
defective battery
defective ON/OFF key
press ON/OFF key
for longer period
no action
taken after
TARE or
HOLD is
pressed
defective TARE or HOLD
key
clean TARE or HOLD
key
unstable readings
scale in motion
stabilize the load and
scale
scale is damped
dry the scale
dust on PCB board
clean PCB board
reading is not in zero
without load
unstable system power
longer warm‐up time
load‐cell was
stressed too much
or too long
hang the scale
in storage
large error in weight
reading
scale is not zeroed
before loading
keep the scale
unloaded and reboot
re‐calibration needed
re‐calibrate the scale
wrong unit
switch to correct unit