7 (38)
3
Installation
3.1
Safety
Caution
This equipment emits RF energy in the ISM (Industrial, Scientific, Medical) band.
Make sure that all medical devices used in proximity to this device meet
appropriate susceptibility specifications for this type of RF energy.
This product is recommended for use in both industrial and domestic environments.
For industrial environments it is mandatory to use the functional earth connection
to comply with immunity requirements. For domestic environments the functional
earth must be omitted if a shielded Ethernet cable is used, in order to meet
emission requirements.
This product contains parts that can be damaged by electrostatic discharge (ESD).
Use ESD prevention measures to avoid damage.
See also additional safety instructions in the included compliance information.
3.2
General Information
Make sure that you have all the necessary information about the capabilities and restrictions of
your local network environment before installation.
The characteristics of the internal antenna should be considered when choosing the placement
and orientation of the unit (unless an external antenna is used).
See
for details about the antenna characteristics.
For optimal reception, wireless devices require a zone between them clear of objects that could
otherwise obstruct or reflect the signal. A minimum distance of 50 cm between the devices
should also be observed to avoid interference.
See also
Wireless Technology Basics, p. 34
Anybus
®
Wireless Bridge II
™
User Manual
SCM-1202-032 EN 1.6