![Anybus CompactCom B40 Network Manual Download Page 33](http://html1.mh-extra.com/html/anybus/compactcom-b40/compactcom-b40_network-manual_2948766033.webp)
31 (54)
Instance (1..n) Attributes
#
Name
Access
Type
Value/Description
1
Name
Get
SHORT_STRING
Parameter name (Including length)
2
ABCC Data
type
Get
Array of USINT
Data type of instance value
3
No. of
Elements
Get
USINT
1 (Number of elements of the specified data type)
4
Descriptor
Get
Array of USINT
Bit field describing the access rights for this instance
Bit:
0
1
2
3
4
5
6
Meaning:
1 = Get Access
1 = Set Access
(reserved, set to 0)
1 = Write process data mapping possible
1 = Read process data mapping possible
1 = NVS parameter
1 = Data notification enabled
5
Value
Get/Set
Determined by
attributes #2, #3
and #9
Instance value
6
Max Value
Get
The maximum permitted parameter value.
7
Min Value
Get
The minimum permitted parameter value.
8
Default Value
Get
The default parameter value.
9
Number of
subelements
Get
Array of UINT
Always 0
Attributes #5–8 are converted to/from CIP standard by the module
Anybus
®
CompactCom
™
B40 Modbus Serial EtherNet/IP Network Guide
SCM-1202-131 1.1 en-US