Programming Instructions
1. Codes are programmed to be 4~6 digits in length. All codes must be the same length.
2. Before inputting any of the following, enter Programming Mode by entering the Master Code twice.
The default master code is 1234.
To enter Programming Mode, enter 1 2 3 4 1 2 3 4
3. To exit Programming Model, press the # key.
4. The keypad will exit Programming Mode if no keys are pressed for 30 seconds.
◆
Programming Tips
• Program a new Master Code immediately.
• Take note of the keypad status LED –
■
LED Solid Amber: Programming Mode
■
LED Solid Green: Awaiting code entry
• If you are unsure of which mode the keypad is in, press # until the LED is off. The keypad is now in
the Standby Mode. Enter the master code twice to return to Programming Mode.
Copyright © All rights reserved. P-MU-DG-750 Published 2019.07.01
Model: DBR-200
COM
NO
INPUT
AC/DC
To Keypad To Keypad
12VDC
12VDC
12 VDC
◆
Sample wiring and applications
Relay 2
Relay 1
Electric Lock 2
Fail-safe Mode
Power Supply Unit
Varistor
Exit Button 2
Electric Lock 1
Fail-secure Mode
Power Supply Unit
Diode
Exit Button1
REED
Door Closed = N.O.
Door Open = N.C.
Tamp(-)
(Anti-tamper alarm function is
triggered at the same time)
12VDC
(Max Current 100mA )
Emergency Light
12~24V Black Red Yellow Green
Black Wire Cable
Power Supply Unit