![Antunes WSS-0948-R Owner'S Manual Download Page 7](http://html.mh-extra.com/html/antunes/wss-0948-r/wss-0948-r_owners-manual_2948353007.webp)
P/N 1011598 Rev. A 11/20
7
RESIDENTIAL WATER SOFTENER
Figure 1.
System Components (need better image of component names)
CAUTION
When placing the unit into service, pay
attention to the following guidelines
:
y
Water Pressure: A minimum of 40 psi
(2.8 bar) of water pressure is required
for the system to operate effectively.
y
Electrical Facilities: An uninterrupted
alternating current (120 VAC)
supply is required. The control
uses a transformer to supply 12
VDC. Please make sure your
voltage supply is compatible with
your unit before installation.
y
Existing Plumbing: Condition of
existing plumbing should be free
from lime and iron buildup. Piping
that is built up heavily with lime and/
or iron should be replaced. If piping
is clogged with iron, a separate
iron filter unit should be installed
ahead of the water softener.
Installation
Suggested Tools and Supplies for
Installation
The following tools and supplies are
suggested to help with the installation:
y
Level
y
Tube Cutter
y
Screw Driver
y
Nut Driver
y
Adjustable Wrenches
y
Thread seal pipe tape
y
Thread seal pipe dope
y
Softener Salt
y
Female adaptors, 1” NPT to
connect to existing plumbing
y
Pipe or tubing to connect
to existing plumbing
NOTE:
If any parts are damaged,
contact Antunes Technical
Service IMMEDIATELY at:
+1-877-392-7854 (toll free).
Unpacking
1.
Remove the softener from packaging
and place on a sturdy work surface.
2.
Remove any packing material from the
inside of the system.
3.
Remove component parts from inside
the brine tank and cartons.
4.
Inspect system for any broken
components or fittings.
Equipment Setup
General
When placing the system into service, pay
attention to the following guidelines:
y
DO NOT immerse cord or
power plug in water.
y
Keep cord away from
heated systems.
Electrical
The line voltage must match the voltage
on the specification label. The plug on the
power cord must match the appropriate
outlet. DO NOT connect the system to a
switched electrical outlet.
Plumbing
NOTE:
The system must be connected
to the COLD water line. DO NOT
connect the system to the hot
water line.
The softener system uses the following
connections:
1.
Locate the softener resin tank and
brine tank on a clean, level, firm
surface. Remember that the tank,
when filled with water, will weigh
over 200 lbs.
NOTE:
If the surface is not level, make
sure to level it with a non-cor
-
rosive material. Wood shims
are not recommended as they
could deteriorate over time.
2.
If you prefer to keep your outside
taps unsoftened, you will need to
install bypass lines for unsoftened
hard water to the outside taps.
3.
Install the top distributor basket to
the control head.
4.
Lubricate the tank o-ring and
distributor o-ring using silicone
lubricant.
5.
Attach the control head to the
resin tank by screwing it onto the
top of the tank. Do NOT use any
thread or pipe sealant on the tank
threads. The control head seals
when the o-ring is fully engaged.
System Inlet
1” NPT Male
System Outlet
(Softened Water)
1” NPT Male
Drain
1/2” ID Hose
Bypass Valve
Distributor Baskert
Power Supply
Yoke
Drain Elbow
Brine Tubing
Brine Tubing
Brine Tank
Lid
Pressure Tank
Control Valve
Brine Tank
Brine Tank
Valve