GST-3V BUN TOASTER
15
P/N 1012002 Rev. B 04/18
TROUBLESHOOTING (continued)
Problem
Possible Cause
Corrective Action
Control Display is blank. Power Cord is not plugged in.
Plug the Power Cord into the appropriate out-
let. Turn the toaster on. If the Control Display is
still blank, contact your maintenance person or
Authorized Service Agency for service.
Circuit Breakers turned off or
tripped. Damaged electrical outlet,
plug, or Power Cord. Power Switch
damaged.
Reset Circuit Breakers. If they trip again, check
the Power Cord, Plug, and outlet for damage.
Contact your maintenance person, Authorized
Service Agency, and Electrician for service.
Faulty Transformer.
Replace Transformer.
Conveyors not turning.
Motor Drive Chain is detached from
sprockets.
Reinstall the Drive Chain.
Drive Chain needs lubrication.
Lubricate Drive Chain with Lubit-8 (P/N 2140152).
Failed Drive Motor.
Contact your maintenance person or Authorized
Service Agency for service.
Control Display flashes
Err 1
,
2
,
3
,
5
,
6
,
7
, or
any number above
Err
20
.
Internal Control Board fault.
The Control Board needs to be replaced. Contact
your maintenance person or Authorized Service
Agency for service.