Maintenance (Continued)
Changing the Interval Setting
Resetting the Timer Program
During the normal operation, the system will flush according to
the set interval. It is possible the system will flush at a time of
high water use. If this poses a problem, the controller can be
reset. Unplug the power supply, wait for 5 seconds, and then
plug the power supply in. When power is restored to the con-
troller, it will automatically enter Flush Mode. The controller will
then begin timing from the point when power is restored based
on the interval setting selected.
Figure 6. Controller
Flush
Interval
Button
Hold Time
Button
LED
Flush
LED
15 minutes
A
10 seconds
On
On
30 minutes
B
10 seconds
On
On
45 minutes
C
10 seconds
On
On
1 hour
A
5 seconds
On
Off
4 hour
B
5 seconds
On
Off
6 hours
C
5 seconds
On
Off
12 hours
D
5 seconds
On
Off
24 hours
D
10 seconds
On
On
Caution
Changing the flush interval can cause the Ultra Filter to plug
prematurely and may reduce the life of the filter. Consult the
factory for more information.
Though not recommended, the Interval Setting on the
controller can be changed. If the setting must be changed,
use the chart below. Press and hold the corresponding button.
After 5 seconds, the Button LED will turn on. After 10 seconds,
the Flush LED will turn on.