Antunes 9210970 Manual Download Page 17

17

P/N 1011446 Rev. B 01/17

WIRING DIAGRAM

BLK

WHT

GRN-YEL

WIRE LEGEND

4

1

2

3

15

BLK

17

WHT/BLK

12

16

WHT

15

B

LK

LI

N

E

LOA

D

12V

33

WHT

14

13

2

1

5

-4

+3

-4

+3

7

9

8

10

1

4

1

2
3
4

1

2
3

22

WHT

21

18

21

21

20

11

19

17

18

20

22

21

WHT/BLK

12

BLU

25

2

3

4

5

6

19

BRN

23

BLK

24

RED

26

YEL

27

WHT

28

34

28

27

26

31

32

29

30

9

6

7

5

25

16

WHT

5

20

POWER

MOV

CORD

WIRING DIAGRAM

GRN/YEL

#12-1,2,3,5,6

YEL/BLK

YEL/BRN

J6

BLK/BRN

SSR 2

SSR 1

BOTTOM

TOP

WHT

WHT

RED

BLU

B

OTTOM

TOP

4070280

J8

J4

BLU/BLK

TOP

BOT

HIGH LIMITS

BLU/BLK

C1

RED/ORG

BLK/BRN

ORG/BLK

BLK

RED/BLK

ORG/BLK

GRN/YEL

RED/BLU

ORG/BRN

RED/

YEL

B

LK/

RED

BLK/BRN

#14-7,8,9,10

#18-4,34
#20-11,12,13,14,15,16

    17,18,19,20,21,22

25,33

#22-23,24,26,27,28,29

30,31,32

2300W

2300W

4600W

50/60Hz

208V

J5

J2

J3

K-TYPE

THERMOCOUPLES

TOP

BOTTOM

L1

T1

T2

L2

FAN

M

T

Summary of Contents for 9210970

Page 1: ...P N 1011446 Rev B 01 17 Flatbread Toaster Model GST 1H Manufacturing Numbers 9210970 9210971 www antunes com ...

Page 2: ... this manual y y Malfunction resulting from improper maintenance y y Damage caused by abuse or careless handling y y Damage from moisture into electrical components y y Damage from tampering with removal of or changing any preset control or safety device TABLE OF CONTENTS Purchased From Date of Purchase Model Number Serial Number Manufacturing Number IMPORTANT A J Antunes Co reserves the right to ...

Page 3: ...t be in accordance with lo cal electrical codes and any other applicable codes y y Do not clean this appli ance with a water jet WARNINGS Be advised of the following warnings when operating and performing mainte nance on this unit y y If the supply cord is damaged it must be replaced by the manu facturer or its service agent or a similarly qualified person in order to avoid a hazard y y Do not mod...

Page 4: ...ev B 01 17 SPECIFICATIONS Model Mfg No Volts Watts Hertz Plug Description GST 1H 9210970 9210971 208 4600 60 L6 30P 30 Amp 250 Volt Straight Twist Lock 23 4 593 4 mm 17 5 443 3 mm 17 25 438 mm 26 661 8 mm 20 510 7 mm ...

Page 5: ...rface Figure 1 Flatbread Toaster GST 1H OPERATION 1 Press and release the Power button to turn the toaster on Allow the toaster to warm up until USE ap pears in the display 2 Insert product into the unit using the feeder 3 Finished product drops onto the heated landing zone Light Dark Adjustments The light dark value can be adjusted when the unit is displaying USE To adjust the light dark value pr...

Page 6: ...o ceed to the Temperature Units 8 To change the Temperatures units from Fahrenheit or Celsius press the LIGHTER or DARKER buttons 9 Press and hold the PROGRAM but ton to save any changes NOTE The unit exits Manager Mode after 30 seconds of keypad inac tivity SAFETY FEATURES Hi Limit Control A Hi Limit Control turns off electrical power to the heaters and control circuits and displays HL if the uni...

Page 7: ...m of tears or discoloration of the belt at which point all belts should be replaced NOTE Belts should be removed ONLY during Belt Replacement or when required in a service situation For proper operation replace all belts at the same time Removing Belts 1 Press and release the Power button to turn the toaster off The toaster enters a cool down mode and will automatically shut down when complete 2 U...

Page 8: ...turning to service CLEANING THE TOP COOLING FAN AND ELEC TRICAL HOUSING ANNU ALLY Follow these steps to clean the top fan 11 Press and release the Power button to turn the toaster off The toaster enters a cool down mode and will automatically shut down when complete 12 Unplug the power cord 13 Facing the front of the toaster move to the left Side Panel Remove the left Side Panel and set aside Do n...

Page 9: ...rized Service Agency for service Worn or damaged Ball Bearings Drive chain or sprockets damaged Failed Motor Failed Control Board Control Display flashes SpEd Mechanical bind in one or both conveyors Enter user mode to check motor speed Check both conveyors for mechanical binds Replace necessary parts Contact your mainte nance person or Authorized Service Agency for service Worn or damaged Ball Be...

Page 10: ...ency and Electrician for service Faulty Transformer Replace Transformer Conveyors not turning Belt is damaged Replace Belts Motor Drive Chain is detached from sprockets Reinstall the Drive Chain Failed Drive Motor Contact your maintenance person or Authorized Service Agency for service Belts are ripped or torn Rollers or Heater Cover Plates are dirty and need to be cleaned Clean Rollers and Heater...

Page 11: ...illa Toaster Line Voltage 1 50 0701003 Wire Harness Tortilla Toaster Heater 1 51 0800438 Rod Belt Cover 4 52 1001658 Label Control 1 53 1031306 Spec Label 9210970 1 54 2000259 Tube O d 1 4 X 1 625 Lg 4 55 2100212 Handle Pocket Pull Snap In 2 56 2100334 Thrust Strip Teflon 4 TEM PART NO DESCRIPTION QTY 57 2140101 Adhesive Sealant Rtv 1 58 2150172 Bearing Shaft 1 4 2 59 2150179 Sprocket 25B14 1 2 Bo...

Page 12: ...12 P N 1011446 Rev B 01 17 18 6 19 55 20 43 72 72 14 40 72 7 72 72 39 72 72 72 72 53 ...

Page 13: ...13 P N 1011446 Rev B 01 17 59 79 24 62 78 78 78 62 37 2 62 11 56 46 35 44 10 46 56 78 1 62 78 3 3 10 46 56 36 12 13 11 56 46 62 78 59 65 61 59 65 61 78 62 37 78 62 36 63 63 63 63 ...

Page 14: ...14 P N 1011446 Rev B 01 17 9 47 32 31 67 68 95 77 91 92 69 70 96 81 93 52 97 66 8 71 73 73 73 94 64 69 60 98 98 64 75 ...

Page 15: ...15 P N 1011446 Rev B 01 17 89 41 75 74 75 42 34 21 22 27 54 89 25 17 89 26 83 86 84 80 99 99 90 27 54 21 34 16 89 42 74 87 45 89 85 86 84 4 75 75 88 ...

Page 16: ...16 P N 1011446 Rev B 01 17 28 29 28 29 38 5 15 51 33 81 76 81 76 81 76 81 76 51 82 81 76 85 86 84 85 86 84 75 82 81 76 23 75 75 85 86 84 85 86 84 30 ...

Page 17: ...27 26 31 32 29 30 9 6 7 5 25 16 WHT 5 20 POWER MOV CORD WIRING DIAGRAM GRN YEL 12 1 2 3 5 6 YEL BLK YEL BRN J6 BLK BRN SSR 2 SSR 1 BOTTOM TOP WHT WHT RED BLU BOTTOM TOP 4070280 J8 J4 BLU BLK TOP BOT HIGH LIMITS BLU BLK C1 RED ORG BLK BRN ORG BLK BLK RED BLK ORG BLK GRN YEL RED BLU ORG BRN RED YEL BLK RED BLK BRN 14 7 8 9 10 18 4 34 20 11 12 13 14 15 16 17 18 19 20 21 22 25 33 22 23 24 26 27 28 29 ...

Page 18: ...18 P N 1011446 Rev B 01 17 NOTES ...

Page 19: ...19 P N 1011446 Rev B 01 17 ...

Page 20: ... warranty does not cover water contamination problems such as foreign material in water lines or inside solenoid valves It does not cover water pressure problems or failures resulting from improper incorrect voltage supply This warranty does not cover Travel Time Mileage in excess of 2 hours 100 miles 160 km round trip from the nearest authorized service agency 2 Roundup reserves the right to make...

Reviews: