![ANTONUS STEP BROTHER User Manual Download Page 18](http://html.mh-extra.com/html/antonus/step-brother/step-brother_user-manual_2948154018.webp)
17
to SEQUENTIAL. Return all other switches to their original
positions.
Now locate the switch labeled “16/1 - 8/2” (H). With the clock
running, move this switch to the “8/2” position. You’ll see that
two lights go on for each step. If you slow the CLOCK FREQ
down for a closer look at what is happening, you should see
that the two lights move in parallel and that one is always in
the first eight positions and the other in positions 9 through
16. You’ll notice from the panel graphics directly above the
lights that the first 8 positions are grouped together by a long
arrow indicated by the letter A. Similarly, positions 9 through
16 are grouped together and called B.
Essentially, the “8/2” mode has broken your 16 step se-
quence into two separate 8 step sequences. Move the SKIP/
OFF/RESET switch to RESET and lower GATE ASSIGN switch
5. Notice that both sections of the sequencer count only four
steps. Raise GATE ASSIGN switch 5, and lower switch 13.
You’ll see that this has exactly the same effect. Try experi-
menting with the RESET and SKIP functions until you are
completely familiar with the operation of the “8/2” counting.
Be sure to keep the CLOCK FREQ low enough so that you can
observe what is going on. When you have finished, return all
the switches to the original position.
Now that you have learned a little about the operation of
your sequencer’s stepping controls and functions, it’s time
to connect the sequencer to your synthesizer and begin ma-
king music.
Even for the simplest patch, you’ll need two connection
cables (see diagram 2). Connect from QUANTIZED OUTPUT A
to the connector labeled CV IN from your Synthesizer. Con-
nect the other cable between the sequencer CLOCK OUT con-
nector and the GATE IN from your synthesizer.
+
+
MULTIPLE
CV INPUT
INPUT A
INPUT B
A
B
GATE
CLOCK
FREQ
CLOCK
OUT
PULSE
WIDTH
FM
PWM
START/
STOP
CLOCK FM
OT SWITCH OUT
AND
GATE
BUS
3
POSITION
1
OUT
CLOCKED
GATE 1
OUT
QUANTIZED
OUTPUT A
QUANTIZER
A
SEQUENCER
OUTPUTS
QUANTIZER
B
QUANTIZED
OUTPUT B
ATTACK
GATE
IN
10
0
ENV
OUT
SYNC
P W
CV IN
OSCILLATOR
VCA 2
ENVELOPE GENERATOR
X 1
X 10
HI
LO
MANUAL
DECAY
SUSTAIN
RELEASE
GATE
BUS
1
VCA 1
OUT
IN
CV
CV INPUT
Connection Panel
ANTONUS 2600
AC IN
CV IN
GATE IN
GATE OUT
AUX CV
MIDI IN
CLOCK
OUT
PULSE
WIDTH
FM
QUANTIZER
A
QUANTIZER
B
GATE
IN
ENV
OUT
CV IN
OSCILLATOR
X 1
X 10
HI
MANUAL
X 1
GATE OUT
AUX CV
MI
I
D
DI
DI
DI
I
I
I
I
I
I
N
N
M
Diagram 2
Summary of Contents for STEP BROTHER