Fill the fuel tank full and turn on your diesel generator (if you are using the mains 
electricity network, go directly to point 

2

).

Connect a current stabiliser to the 120/230 V (alternating current) electrical power 
socket, and switch it on.

Connect the WATA-Plus

®

 device to the 12 V/29.2 A power supply.

Connect the 12 V/29.2 A power source to the stabiliser and turn the power source’s 
green switch to on.

Wait 4 hours to generate 15 litres of sodium hypochlorite solution (6 g/L).

At the end of the process, turn the power source green switch to off. Disconnect the  
12 V/29.2 A power supply from the stabiliser. 

Remove the WATA-Plus

®

 device from the bath, and then disconnect the 2 WATA-Plus

®

 

cables. Turn the stabiliser’s switch to off.

Unplug the stabiliser from the wall socket. Rinse the WATA-Plus

®

 device in clean water, 

then store it out of harm’s way in a dry place. Protect it by covering with a clean cloth.

6.2 PREPARING THE SOLUTION FOR ELECTROLYSIS 
WITH COARSE OR DIRTY SALT (15L BASE)

Pour 3 litres of clean water into a clean plastic container.

Add 375 grams of salt.

Regularly shake/mix for 15 minutes so that the maximum amount of salt dissolves.

Allow the salt’s impurities to settle at the bottom of the container. At this point, the 
salt is dissolved in the water.

Pour 12 litres of water into a plastic container (never use metal).

Place a filter (e.g. a coffee filter or a clean, very finely-woven cloth) over the container 
and add the 3 litres of water containing the pre-dissolved salt. Mix well.

Immerse the body of the WATA-Plus

®

 in the salt water: the handle should remain out of 

the water, but the body of the device should be completely submerged.

6.3 INSTALLING AND CONNECTING 
THE WATA-PLUS

®

 DEVICE

 

W

You are advised to install a stabiliser between the power source and the 12 V/29.2 A 
power source. Have the electrical system’s stability inspected by a specialist. 

 

W

Using a diesel generator (or generator unit), the recommended minimum power is  
3 kW/kVA.

 

W

The power source must be located as far as possible away from the water-
production container, so as to protect it from the highly-corrosive chlorine vapour. 
The power source must not be laid on the ground. Ideally, it should be placed in a 
room other than the chlorine production room.

3 L

1

2

3

4

12 L

3 L

15 L

WATA-Plus

www.antenna.ch

5

6

7

WATA-Plus

www.antenna.ch

6 m

Power  
supply

2

1

3

4

15 L = 4h

WATA-Plus

www.antenna.ch

5

6

7

8

Generator (unit) 

min. 3 kW

Stabiliser 

WATA-Plus

®

Summary of Contents for WATA-Plus

Page 1: ...WATA Plus OPERATING INSTRUCTIONS WATER AND HYGIENE WATA Plus www antenna ch...

Page 2: ...W The device should be used only by a responsible person familiar with this user guide W The sodium hypochlorite solution can be corrosive and irritating when in contact with skin eyes mucosa and air...

Page 3: ...e production and to trace the origin of any problems that might arise use a log book to record each time the WATA Plus is used the name of the person responsible for production the starting and finish...

Page 4: ...ll ventilated to dissipate W Precautions Do not bend the power cables W Maintenance and repair Do not attempt to perform electrical repairs if you are not competent to do so Contact Antenna or a speci...

Page 5: ...mount of solar radiation WATA Plus www antenna ch Photovoltaic module Regulator STECA solarix PRS3030 WATA Plus Sealed battery SOLAR MODULE CHOOSING THE BATTERY CAPACITY NEEDED AH Minimum capacity nee...

Page 6: ...at the maximum amount of salt dissolves 4 Allow the salt s impurities to settle at the bottom of the container At this point the salt is dissolved in the water 5 Pour 12 litres of water into a plastic...

Page 7: ...YY X CONTROL REAGENT FOR AVAILABLE CHLORINE R ACTIF DE CONTR LE DU CHLORE ACTIF DE SOLUTION DE CHLORE ANTENNA CH 6 4 WATA PLUS MAINTENANCE After each use rinse the WATA Plus with clean water With time...

Page 8: ...ive chlorine concentration using the WataTest 3 g L 5 0 mL 10 0 mL 50 0 mL 4 g L 3 8 mL 7 5 mL 37 5 mL 5 g L 3 0 mL 6 0 mL 30 0 mL 6 g L 2 5 mL 5 0 mL 25 0 mL 7 g L 2 1 mL 4 3 mL 21 4 mL W It is absol...

Page 9: ...be diluted in cold water W Never mix the sodium hypochlorite solutions with soap detergents or other household cleaning products since mixing with strong acids generates chlorine gas fumes All the sci...

Page 10: ......

Page 11: ...ANTENNA FOUNDATION Av de la Grenade 24 CH 1207 Gen ve T 41 22 737 12 40 Email wata antenna ch WWW ANTENNA CH 2017...

Reviews: