13
3.
‘MP32 detected’ display (indicates if an MP32 unit is connected to your )
4.
Meter Source display (dropdown tab allows you to select different sources to preview)
5. Clock Source
This dropdown menu allows you to select how the is to be synchronized. Select
Oven/10M for internal sync (with or without atomic clock reference), W.C. (Word Clock) to sync
the to an external device through the Word clock input, or MADI, ADAT, S/PDIF for
syncing with incoming digital signals.
Once Atomic Clock is connected it replaces ‘Oven’ in the Clock Source dropdown menu.
supports sample rates higher than 48kHz for MADI and ADAT and also supports S-Mux.
The following tables show what the various options for MADI and ADAT implement in order to be
consistent with the input/output of your other devices connected via MADI or ADAT.
Clock Source MADI Options (with or without the S-Mux option selected in Settings):
Clock Source Mode
MADI Configuration
Sample Rate
Channels
MADI
44.1 kHz
64 ch
48 kHz
64 ch
MADI 2X
88.2 kHz
32 ch
96 kHz
32 ch
MADI 4X
176.4 kHz
16 ch
192 kHz
16 ch
Clock Source ADAT options: (Note that there is no S-Mux check-box for ADAT as it is
automatically enabled when you select ADAT 2X or ADAT 4X):
Clock Source Mode
ADAT Configuration
Sample Rate
Channels
ADAT
44.1 kHz
8 ch
48 kHz
8 ch
ADAT 2X
88.2 kHz
4 ch
96 kHz
4 ch
ADAT 4X
176.4 kHz
2 ch
192 kHz
2 ch
6. Sample Rate select
7. Lock light
8. Presets
9. Settings
Summary of Contents for Orion32+