ANTEK FU 3 AE-03 Operating Manual Download Page 2

Operating Manual – Digital Frequency Converter 

Page 2 of 14

09/99   R0048GB.doc

       Antriebstechnik GmbH

1. 

Important Pre-operation information

1.1 Safety information

Electrical units are a source of danger.

Comply with the relevant laws and regulations when electrical units
are used in installations and control systems which require
observation of safety rules, and when carrying out installation work.

When working on live units, always comply with the current accident
prevention regulations.

For reasons of safety and in order to maintain the documented
system data and functions the unit or its components may only be
repaired by the manufacturer.

No liability can be accepted if the drive parameters have an
unsuitable, incorrect manual or automatic setting.

Incorrect handling may cause injuries and/or damage property!

Prior to installation technicians who are familiar with electrical drive
equipment must read the unit handbook thoroughly.

Ensure that the voltage is not dangerous before touching electrical
contacts.

The user must use independent monitoring units in order to ensure
that a malfunctioning drive is stopped safely.

The user is responsible for installing and connecting the motor, the
converter and auxiliary units pursuant to the acknowledged technical
rules in the country of installation and other current regional
regulations. In particular, cable dimensioning, shielding, earthing,
disconnection, isolation and overcurrent protection must be taken
into account.

Regulations pursuant to DIN 57100 are applicable.

The modules are fitted with electrostatically sensitive CMOS and
MOS components. Always comply with the following information
when handling and testing the units, otherwise these integrated
circuits may be damaged.

Š

 When servicing the unit, first ensure that there is equipotential

bonding (static charging) between the unit, tools, measuring
instruments and personnel.

Š

 Take hold of the modules only by the edges; do not touch the

components or their connections.

Summary of Contents for FU 3 AE-03

Page 1: ...ncy Converter FU 3 AE 03 Digital Frequency converter for stepless speed control of 3 phase a c motors up to 1 1 kW 1 Important Pre operation information 2 2 Brief description 5 3 Specification FU 3 AE...

Page 2: ...equipment must read the unit handbook thoroughly Ensure that the voltage is not dangerous before touching electrical contacts The user must use independent monitoring units in order to ensure that a...

Page 3: ...ation in card racks The unit must be installed vertically The air flow of the unit must not be obstructed The air inlet and outlet must be kept clear Important information regarding protective earthin...

Page 4: ...from signal lines are to be laid two way source and target large area and well conducting to a ground 1 In case of poor potential equalization between shielded connections an additional balancing net...

Page 5: ...rack mount with 3 standard european boards 160 mm Integrated switching power supply Advantages Compact and space saving type as 3HE 19 insert Operation with industry standard motors min Inductivity 2m...

Page 6: ...ons 100 Efficiency at nominal load ca 95 Power loss at no load ca 20 W Power loss nominal load ca 60 W Clock frequency of output transformer ca 3 9 kHz Digital Control inputs Reglerfreigabe Reset Faul...

Page 7: ...1 8 PE X1 11 L1 Supply voltage connection 3x 400 VAC 10 480 VAC 6 X1 14 L2 50 60 Hz X1 17 L3 External fuse 3x 10 A Z characteristics Wire behind the main filter must always be shielded X1 20 UZK Inter...

Page 8: ...n speed set point 0 10 VDC Ri 10 k reference GND X2 22a Warning This connection always must be shielded X2 18a Tacho Connection for pulse generator Warning This connection always must be shielded Auxi...

Page 9: ...2 3 X1 L1 L2 L3 M ain connectu ib 3x 400 VAC 1 0 480 VAC 6 5 0 60 H z Pre fuse ABB S283 Z10 11 14 17 X1 26 29 32 X1 M 3 DT SE 5 X1 2 24VD C Voltage supply X2 2a X2 4a X2 1 0a X2 1 2a X2 1 8a R ight L...

Page 10: ...has detected the r p m difference Threshold ca 1 5 from n max Relay contacts opened X2 26a and X2 28a LEFT YE Indicates Enable left Pin X2 2a RIGHT YE Indicates Enable right Pin X2 4a 5 3 Measuring po...

Page 11: ...Start Run Search click on Set up on drive A and confirm with Open 4 Click OK to start Installation The Set up Menu recommends the folder ANTEK confirm with Beenden 5 Set up installs the program in the...

Page 12: ...s frequency Regler Frequency conversion combined with r p m regulation U Netz Mains input voltage Range 0 480 VAC Caution Re check parameters after changing mains input voltage Boost Compensation for...

Page 13: ...requency Hz p number of pole pairs z number of increments resolution P Anteil I Anteil Regulating behaviour Range 0 00 10 Achtung Improper regulator parameters can cause the drive to oscillate Schwell...

Page 14: ...voltage Check mains voltage Check circuit breakers and fuses Cable fault Check motor phases Thermo switch in Motor has tripped Allow motor to cool Reduce motor load Check cooling Boost setting in Ste...

Reviews: