Antari IP-1500 Manual Download Page 14

 

Ordercode: 60899 

Antari IP-1500 

4. Timer output settings (Timer mode) 

With this menu, you can set the volume of the fog output in Timer mode. 

 

01)

 

Press the 

 button until the display shows 

02)

 

Press the 

 buttons to set the volume. The adjustment range is between 1-100% (from small 

to big output). 

 

 

5. Continuous output volume settings (Continuous mode) 

With this menu you can set the volume of the fog output in Continuous mode. 

 

01)

 

Press the 

 button until the display shows 

02)

 

Press the 

 buttons to choose between 1-100% (from small to big output) and NONSTOP 

BURST (continuous output). 

 

 

6. DMX settings 

With this menu, you can set the starting address of the Antari IP-1500. 

 

01)

 

Press the 

 button until the display shows 

02)

 

Press the 

 buttons to set the desired DMX address. The adjustment range is between 001-

512. 

 

 

7. Wireless settings 

With this menu, you can set whether the device reacts to the remote control. Please, see page 14 for 

more information on the remote control operations. 

 

01)

 

Press the 

 button until the display shows 

02)

 

Press the 

 buttons to choose between ON and OFF. 

 

 

8. Fluid sensor 

With this menu, you can set the fluid sensor. It will react to the fog fluid level and will notify the user if the 

fluid level is low. 

 

01)

 

Press the 

 button until the display shows 

02)

 

Press the 

 buttons to choose between ON and OFF. 

03)

 

When this option is active, the display will show 

, whenever the fog fluid level is low. 

 

 

9. Quick start 

With this menu, you can set whether the device remains idle on start-up or if it runs in the previously active 

mode. 

 

01)

 

Press the 

 button until the display shows 

02)

 

Press the 

 buttons to choose between ON and OFF. 

03)

 

On start-up, when this option is switched ON, the device will run the mode which was active when 

the power supply was switched off. 

04)

 

When this option is switched OFF, the device will remain idle. 

 

 

  

 

 

13 

   

 

Summary of Contents for IP-1500

Page 1: ...Antari IP 1500 V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 60899 MANUAL ENGLISH...

Page 2: ...Controllers DMX Control 9 Data Cabling 10 Control Panel 10 Control Mode 10 DMX Addressing 10 Menu Overview 11 Start up settings 11 Main Menu Options 12 1 Control modes 12 2 Interval settings Timer mo...

Page 3: ...cable length 1 5 m 1 x PU pipe Wireless remote control 1 x safety eye 2 x adjustment screw 1 x mounting bracket User manual Safety Instructions Every person involved with the installation operation a...

Page 4: ...ut sleeve in place if the machine is to be used in the presence of children Always keep the fog output at least 50 cm away from contact with anything while in operation Always disconnect power from th...

Page 5: ...ied out by an authorized dealer Procedure If the fog machine is lowered from the ceiling or high joints professional trussing systems have to be used Use a clamp to mount the fog machine with the moun...

Page 6: ...mber 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this che...

Page 7: ...0 cu ft min Fluid consumption 11L min Power connection Schuko DMX control 1 channel 5 pin DMX signal connector IN Included wireless remote control Warm up time 10 min IP rating IP63 Dimensions 460 x 2...

Page 8: ...de Fig 02 05 Schuko power cable 06 Fog fluid IN 07 Circuit breaker 08 5 pin DMX signal connector IN 09 Wireless receiver 10 Safety eye included 11 LCD display menu buttons Remote control 12 A button 1...

Page 9: ...in horizontal position Always disconnect from electric mains power supply before cleaning or servicing Damages caused by non observance are not subject to warranty Set Up and Operation Before plugging...

Page 10: ...ion about Timer mode and Continuous mode Multiple Controllers DMX Control 01 Fasten the effect light to a firm trussing Leave at least 0 5 meter on all sides for air circulation 02 Always use a safety...

Page 11: ...Ordercode FL0975 0 75 m FL09150 1 5 m FL093 3 m FL096 6 m FL0910 10 m FL0915 15 m FL0920 20 m DAP Audio DMX adapter 3 pin 5 pin Ordercode FLA30 Control Panel The Antari IP 1500 can be operated with a...

Page 12: ...ivate wireless control 05 After 15 seconds the display will show Now it is not possible to activate any remote controls anymore 06 The display will now show The warm up process will take up to 10 minu...

Page 13: ...sen the desired control mode the device will start fog output using the settings below 04 Press the button to stop output 2 Interval settings Timer mode With this menu you can set the intervals betwee...

Page 14: ...ngs With this menu you can set whether the device reacts to the remote control Please see page 14 for more information on the remote control operations 01 Press the button until the display shows 02 P...

Page 15: ...is switched ON the device will shut down if it stops receiving DMX signal When the device receives DMX signal it will resume operation Remote control Fig 08 Make sure that wireless control is active P...

Page 16: ...s free of clogs 02 Remove all fog liquid from machine Add cleaning solution to tank Plug unit in 03 Run unit in a well ventilated area until tank is empty 04 Refill with fog liquid Performance Note Fo...

Page 17: ...ing bracket included Housing Die cast aluminum powder coat finish Power connection Schuko Onboard LCD display for easy setup DMX channels 1 channel DMX control via DMX light controller Remote control...

Page 18: ...Ordercode 60899 Antari IP 1500 Dimensions 17...

Page 19: ...Ordercode 60899 Antari IP 1500 18...

Page 20: ...2015 Antari...

Reviews: