Data Cabling 

To link fixtures together, you must obtain data cables. You can purchase DAP Audio certified DMX cables 

directly from a dealer/distributor or construct your own cable. If you choose to create your own cable, 

please use data-grade cables that can carry a high quality signal and are less prone to electromagnetic 

interference. 

 

DAP Audio DMX Data Cables 

 

DAP Audio Basic microphone cable for allround use. bal. XLR/M 3-pin > XLR/F 3-pin.  

Ordercode FL01150 (1,5 m), FL013 (3 m), FL016 (6 m), FL0110 (10 m), FL0115 (15 m), FL0120 (20 m). 

 

DAP Audio X-type data cable XLR/M 3-pin > XLR/F 3-pin. Ordercode FLX0175 (0,75 m), 

FLX01150 (1,5 m), FLX013 (3 m), FLX016 (6 m), FLX0110 (10 m). 

 

DAP Audio cable for the demanding user with exceptional audio-qualities and connector made by 

Neutrik®. Ordercode FL71150 (1,5 m), FL713 (3 m), FL716 (6 m), FL7110 (10 m). 

 

DAP Audio cable for the demanding user with exceptional audio-qualities and connector made by 

Neutrik®. Ordercode FL7275 (0,75 m), FL72150 (1,5 m), FL723 (3 m), FL726 (6 m), FL7210 (10 m). 

 

DAP Audio 110 Ohm cable with digital signal transmission. Ordercode FL0975 (0,75 m), 

FL09150 (1,5 m), FL093 (3 m), FL096 (6 m), FL0910 (10 m), FL0915 (15 m), FL0920 (20 m).   

 

DAP Audio DMX adapter: 3-pin/5-pin. Ordercode FLA30. 

 

 

Control Panel 

The Antari IP-1500 can be operated with a light controller in control mode or without the controller in 

stand-alone mode

 

 

A)  LCD display 

B)  FUNCTION button 

C)  TIMER button 

D)  VOLUME button 

E)   STOP button 

 

 

Fig. 07 

 

 

Control Mode 

The fixture is individually addressed on a data-link and connected to the controller.  

The fixture responds to the DMX signal from the controller. (When you select the DMX address and save it, 

the controller will display the saved DMX address, next time.) 

 

DMX Addressing 

The control panel on the front side of the base allows you to assign DMX fixture address, which is the first 

channel with which the Antari will respond to the controller. 

Please note, when you use the controller, the unit has 1 channel. 

 

Controlling: 

Note: After switching on, the Controller will automatically detect whether DMX 512 data is received or 

not.  

If DMX signal is not received, the problem may be: 

 

The XLR cable from the controller is not connected with the input of the Antari IP-1500. 

 

The controller is switched off or defective, the cable or connector is detective, or the signal wires are 

swapped in the input connector. 

 

 

  

 

 

10 

   

 

Summary of Contents for IP-1500

Page 1: ...Antari IP 1500 V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 60899 MANUAL ENGLISH...

Page 2: ...Controllers DMX Control 9 Data Cabling 10 Control Panel 10 Control Mode 10 DMX Addressing 10 Menu Overview 11 Start up settings 11 Main Menu Options 12 1 Control modes 12 2 Interval settings Timer mo...

Page 3: ...cable length 1 5 m 1 x PU pipe Wireless remote control 1 x safety eye 2 x adjustment screw 1 x mounting bracket User manual Safety Instructions Every person involved with the installation operation a...

Page 4: ...ut sleeve in place if the machine is to be used in the presence of children Always keep the fog output at least 50 cm away from contact with anything while in operation Always disconnect power from th...

Page 5: ...ied out by an authorized dealer Procedure If the fog machine is lowered from the ceiling or high joints professional trussing systems have to be used Use a clamp to mount the fog machine with the moun...

Page 6: ...mber 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this che...

Page 7: ...0 cu ft min Fluid consumption 11L min Power connection Schuko DMX control 1 channel 5 pin DMX signal connector IN Included wireless remote control Warm up time 10 min IP rating IP63 Dimensions 460 x 2...

Page 8: ...de Fig 02 05 Schuko power cable 06 Fog fluid IN 07 Circuit breaker 08 5 pin DMX signal connector IN 09 Wireless receiver 10 Safety eye included 11 LCD display menu buttons Remote control 12 A button 1...

Page 9: ...in horizontal position Always disconnect from electric mains power supply before cleaning or servicing Damages caused by non observance are not subject to warranty Set Up and Operation Before plugging...

Page 10: ...ion about Timer mode and Continuous mode Multiple Controllers DMX Control 01 Fasten the effect light to a firm trussing Leave at least 0 5 meter on all sides for air circulation 02 Always use a safety...

Page 11: ...Ordercode FL0975 0 75 m FL09150 1 5 m FL093 3 m FL096 6 m FL0910 10 m FL0915 15 m FL0920 20 m DAP Audio DMX adapter 3 pin 5 pin Ordercode FLA30 Control Panel The Antari IP 1500 can be operated with a...

Page 12: ...ivate wireless control 05 After 15 seconds the display will show Now it is not possible to activate any remote controls anymore 06 The display will now show The warm up process will take up to 10 minu...

Page 13: ...sen the desired control mode the device will start fog output using the settings below 04 Press the button to stop output 2 Interval settings Timer mode With this menu you can set the intervals betwee...

Page 14: ...ngs With this menu you can set whether the device reacts to the remote control Please see page 14 for more information on the remote control operations 01 Press the button until the display shows 02 P...

Page 15: ...is switched ON the device will shut down if it stops receiving DMX signal When the device receives DMX signal it will resume operation Remote control Fig 08 Make sure that wireless control is active P...

Page 16: ...s free of clogs 02 Remove all fog liquid from machine Add cleaning solution to tank Plug unit in 03 Run unit in a well ventilated area until tank is empty 04 Refill with fog liquid Performance Note Fo...

Page 17: ...ing bracket included Housing Die cast aluminum powder coat finish Power connection Schuko Onboard LCD display for easy setup DMX channels 1 channel DMX control via DMX light controller Remote control...

Page 18: ...Ordercode 60899 Antari IP 1500 Dimensions 17...

Page 19: ...Ordercode 60899 Antari IP 1500 18...

Page 20: ...2015 Antari...

Reviews: